Improvement in left atrial strain among patients undergoing percutaneous left atrial appendage closure
Authors:
Open Access
- 1 January 2020
- journal article
- research article
- Published by Medknow in Journal of Cardiovascular Echography
- Vol. 30 (1) , 15-21
Abstract
Background: Various clinical trials provide evidence about the safety, effectiveness, and therapeutic success of percutaneous left atrial appendage closure (LAAC) using various occlusion devices. These devices are foreign materials implanted into the left atrium and may deteriorate left atrial (LA) function. The aim of this study was to evaluate the change in transesophageal echocardiography (TEE)-derived LA strain after LAAC. Methods and Results: The study included 95 patients (age: 75 ± 6.7 years, 67% male) who underwent percutaneous LAAC. LA strain was evaluated at three different time intervals by TEE (baseline, 45 days, and 180 days after the procedure). All data were analyzed using the software Image-Arena (TomTec®). Seventy patients had atrial fibrillation, whereas 25 were in sinus rhythm at baseline and during follow-up. Analysis was performed for peak atrial longitudinal strain (PALS) and peak atrial contraction strain (PACS) from segments of the lateral wall in mid-esophageal four-chamber view. PACS was obtained in patients with sinus rhythm during examinations. Compared to baseline, PALS increased at 45 days after the procedure (12.4% ± 8.4% at baseline vs. 16.0% ± 10.6% after 45 days, P = 0.001) and remained stable from 45 days to 180 days after procedure (13.8% ± 9.1% after 45 days vs. 17.2% ± 12.6% after 180 days, P = 0.092). Similarly, PACS increased at 45 days after the procedure (5.8% ± 3.9% at baseline vs. 10.6% ± 7.6% after 45 days, P = 0.001) and remained stable from 45 days to 180 days after the procedure (7.6% ± 4.5% after 45 days vs. 7.9% ± 3.1% after 180 days, P = 0.876).Conclusions: Our study demonstrated for the first time the improvement in TEE-derived LA strain following LAAC within 45 days of implantation. The findings suggest improved LA function following LAAC.Keywords
This publication has 26 references indexed in Scilit:
- The Left Atrial Appendage: Anatomy, Function, and Noninvasive EvaluationJACC: Cardiovascular Imaging, 2014
- Prospective Randomized Evaluation of the Watchman Left Atrial Appendage Closure Device in Patients With Atrial Fibrillation Versus Long-Term Warfarin TherapyJACC, 2014
- Prognostic implications of global LV dysfunction: a systematic review and meta-analysis of global longitudinal strain and ejection fractionHeart, 2014
- Percutaneous Left Atrial Appendage Closure With the AMPLATZER Cardiac Plug Device in Patients With Nonvalvular Atrial Fibrillation and Contraindications to Anticoagulation TherapyJACC, 2013
- Percutaneous Left Atrial Appendage Closure for Stroke Prophylaxis in Patients With Atrial FibrillationCirculation, 2013
- The WATCHMAN Left Atrial Appendage Closure Device for Atrial FibrillationJournal of Visualized Experiments, 2012
- Risk of Bleeding With 2 Doses of Dabigatran Compared With Warfarin in Older and Younger Patients With Atrial FibrillationCirculation, 2011
- Impact of left atrial appendage exclusion on left atrial functionThe Journal of Thoracic and Cardiovascular Surgery, 2007
- Left atrial structure and function after percutaneous left atrial appendage transcatheter occlusion (PLAATO)JACC, 2004
- Left atrial appendage: structure, function, and role in thromboembolismHeart, 1999