Continuous bone loss around a tapered uncemented femoral stem: A long-term evaluation with DEXA
Open Access
- 1 January 2006
- journal article
- research article
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 77 (6) , 877-885
Abstract
Background Periprosthetic bone loss is a well-docu-mented phenomenon after uncemented total hip arthroplasty (THA); however, little is known about how bone mineral density (BMD) changes after 2 years. Patients and methods 14 patients with hip arthrosis (group A) were operated with a proximally porous- and hydroxyapatite-coated stem and followed for 10 years with DEXA, radiographs and Harris hip score (HHS). Another group of 14 patients (group B) was evaluated at 6 and 14 years using the same prosthesis and protocol. Results No stem was revised and all stems were well-Fixed. At final follow-up, HHS was 97 points in group A after 10 years and 94 points in group B after 14 years. Bone mineral changes in group A were greatest in Gruen zones 1 and 7, where the losses were 31% and 26%, respectively, after 2 years on the operated side. The decrease in BMD continued after 2 years and in Gruen zone 7 it was faster than the rate of bone loss on the control side. In group B, the annual change in BMD on the operated side was not significantly different from the bone loss in group A. Interpretation Up to 14 years after implantation of a tapered uncemented stem, the BMD in the calcar region continues to decrease faster than would be expected from normal ageing.Keywords
This publication has 59 references indexed in Scilit:
- Total hip arthroplasty with an uncemented hydroxyapatite-coated tapered titanium stem: results at a minimum of 10years’ follow-up in 104 hipsJournal of Orthopaedic Science, 2006
- Periprosthetic proximal bone loss after uncemented hip arthroplasty is related to stem size: DXA measurements in 138 patients followed for 2–7 yearsActa Orthopaedica, 2006
- Cementless total hip arthroplasty using a threaded cup and a rectangular tapered stemThe Journal of Bone and Joint Surgery. British volume, 2005
- Periprosthetic fractures of the greater trochanter through osteolytic cysts with uncemented MicroStructured Omnifit prosthesisActa Orthopaedica, 2005
- High survival rate of hydroxyapatite-coated hip prostheses100 consecutive hips followed for 10 yearsActa Orthopaedica, 2004
- Gothenburg Osseointegrated Hip ArthroplastyClinical Orthopaedics and Related Research, 1998
- Vergleichende periprothetische Knochendichtemessungen am proximalen Femurschaft mittels Dual Energy X-ray-Absorptiometry (DEXA) mit experimenteller “Press Fit-Gleitschaftprothese”*Zeitschrift für Orthopädie und ihre Grenzgebiete, 1998
- Evaluation of periprosthetic bone using dual-energy X-ray absorptiometry: Precision of the method and effect of operation on bone mineral densityJournal of Bone and Mineral Research, 1996
- Closeness of fit of uncemented stems improves the strain distribution in the femurJournal of Orthopaedic Research, 1995
- Age- and sex-related changes in iliac cortical bone mass and remodelingBone, 1993