Geometric correction of cone beam computed laminography based on projected address translation
- 19 September 2024
- journal article
- Published by Optica Publishing Group in Applied Optics
- Vol. 63 (27) , 7329
Abstract
Precise alignment of the system scan geometry is crucial to the reconstruction quality of computed laminography (CL). Different from computed tomography (CT), a challenging task for CL image reconstruction is to deal with rotational axes that are no longer symmetrical. In this paper, we take advantage of the fact that the difference between the inverse of the projected transverse coordinates of two points rotated about the axis of rotation under the CL scan geometry sums to zero when the projection angle differs by 180 deg. Based on this fact, the projection data under the scanned geometry with errors are aligned to the theoretical projection geometry. To validate this calibration method, a numerical printed circuit board (PCB) phantom was simulated. The results demonstrate that this method is capable of achieving high accuracy compared to the previous methods. The experimental results on printed circuit boards (PCB) demonstrate that the method can effectively improve geometric alignment accuracy of CL and obtain high-resolution reconstructed images.Keywords
Funding Information
- Anhui Province Key Research and Development Program of China (202304a05020013)
- National Key Research and Development Program of China (2023YFF0715502)
This publication has 31 references indexed in Scilit:
- Cone beam computed laminography based on adaptive-weighted dynamic-adjusted relative total variationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2023
- Integrating expert feedback on the spot in a time-efficient explorative CT scanning workflow for cultural heritage objectsJournal of Cultural Heritage, 2021
- Image quality determination of a novel digital detector for X-ray imaging and cone-beam computed tomography applicationsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2020
- Spatial resolution of a laboratory based X-Ray cone-beam laminography scanning system for various trajectoriesNDT & E International, 2020
- Improved Vinegar & Wellington calibration for estimation of fluid saturation and porosity from CT images for a core flooding test under geologic carbon storage conditionsMicron, 2019
- Multi-contrast diffraction enhanced computed laminography at Beijing Synchrotron Radiation FacilityAnalytical and Bioanalytical Chemistry, 2018
- A practical method to calibrate the slant angle of central X-ray for laminography scanning systemNDT & E International, 2014
- Iterative geometric calibration in circular cone-beam computed tomographyOptik, 2014
- An interval subdividing based method for geometric calibration of cone-beam CTNDT & E International, 2013
- A calibration method for misaligned scanner geometry in cone-beam computed tomographyNDT & E International, 2006