Abstract
This paper describes an earth-rock dam whose filters’ characteristics did not comply with the design criterion. In addition, the degree of compaction and the water content in the impervious core consisted of highly plastic residual clay. Although Terzaghi’s filter design criterion was used, the as-built grain size distribution did not comply with such criterion. Several problems arose right after the first filling of the dam, including the following: (1) water leak at a rate of 200 L/s was observed along the downstream slope, in the vicinity of the outlet pipeline; the dark color of the observed water implied that the core material was being eroded; (2) two sinkholes near the crest (20 m apart) were observed along the outlet axis, one on the upstream and the other on the downstream slopes; right after the occurrence of these two sinkholes, the water leakage decreases significantly, noticing a plugged effect of the material that falls down through the sinkholes. To avoid piping, a notch was installed on th...