Internal Erosion and Rehabilitation of an Earth-Rock Dam
- 1 February 2011
- journal article
- Published by American Society of Civil Engineers (ASCE) in Journal of Geotechnical and Geoenvironmental Engineering
- Vol. 137 (2) , 150-160
Abstract
This paper describes an earth-rock dam whose filters’ characteristics did not comply with the design criterion. In addition, the degree of compaction and the water content in the impervious core consisted of highly plastic residual clay. Although Terzaghi’s filter design criterion was used, the as-built grain size distribution did not comply with such criterion. Several problems arose right after the first filling of the dam, including the following: (1) water leak at a rate of 200 L/s was observed along the downstream slope, in the vicinity of the outlet pipeline; the dark color of the observed water implied that the core material was being eroded; (2) two sinkholes near the crest (20 m apart) were observed along the outlet axis, one on the upstream and the other on the downstream slopes; right after the occurrence of these two sinkholes, the water leakage decreases significantly, noticing a plugged effect of the material that falls down through the sinkholes. To avoid piping, a notch was installed on th...Keywords
This publication has 4 references indexed in Scilit:
- Assessing the Potential of Internal Instability and Suffusion in Embankment Dams and Their FoundationsJournal of Geotechnical and Geoenvironmental Engineering, 2008
- Assessing Embankment Dam Filters That Do Not Satisfy Design CriteriaJournal of Geotechnical and Geoenvironmental Engineering, 2001
- Critical Filters for Impervious SoilsJournal of Geotechnical Engineering, 1989
- Discussion of “ Hydraulic Fracturing in Embankment Dams ” by James L. Sherard (October, 1986, Vol. 112, No. 10)Journal of Geotechnical Engineering, 1988