Cerebral blood volume sensitive layer-fMRI in the human auditory cortex at 7T: Challenges and capabilities
Authors:
Open Access
- 9 February 2023
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 18 (2) , e0280855
Abstract
The development of ultra high field fMRI signal readout strategies and contrasts has led to the possibility of imaging the human brain in vivo and non-invasively at increasingly higher spatial resolutions of cortical layers and columns. One emergent layer-fMRI acquisition method with increasing popularity is the cerebral blood volume sensitive sequence named vascular space occupancy (VASO). This approach has been shown to be mostly sensitive to locally-specific changes of laminar microvasculature, without unwanted biases of trans-laminar draining veins. Until now, however, VASO has not been applied in the technically challenging cortical area of the auditory cortex. Here, we describe the main challenges we encountered when developing a VASO protocol for auditory neuroscientific applications and the solutions we have adopted. With the resulting protocol, we present preliminary results of laminar responses to sounds and as a proof of concept for future investigations, we map the topographic representation of frequency preference (tonotopy) in the auditory cortex.Keywords
All Related Versions
Funding Information
- National Institutes of Health (RF1MH116978-01)
- HORIZON EUROPE European Research Council (101001270)
- Nederlandse Organisatie voor Wetenschappelijk Onderzoek (016.Veni.198.032)
This publication has 87 references indexed in Scilit:
- Improving diffusion MRI using simultaneous multi-slice echo planar imagingNeuroImage, 2012
- Change of the cerebrospinal fluid volume during brain activation investigated by T1ρ-weighted fMRINeuroImage, 2010
- Three dimensional echo-planar imaging at 7 TeslaNeuroImage, 2010
- Multiband multislice GE‐EPI at 7 tesla, with 16‐fold acceleration using partial parallel imaging with application to high spatial and temporal whole‐brain fMRIMagnetic Resonance in Medicine, 2010
- Cortical depth dependence and implications on the neuronal specificity of the functional apparent diffusion coefficient contrastNeuroImage, 2009
- High-field fMRI unveils orientation columns in humansProceedings of the National Academy of Sciences, 2008
- Improved cortical-layer specificity of vascular space occupancy fMRI with slab inversion relative to spin-echo BOLD at 9.4 TNeuroImage, 2008
- VASO‐based calculations of CBV change: Accounting for the dynamic CSF volumeMagnetic Resonance in Medicine, 2008
- Robust detection of ocular dominance columns in humans using Hahn Spin Echo BOLD functional MRI at 7 TeslaNeuroImage, 2007
- Applications and limitations of whole‐brain MAGIC VASO functional imagingMagnetic Resonance in Medicine, 2007