Validation of Lumbar Compressive Force Simulation in Forward Flexion Condition
Open Access
- 13 January 2021
- journal article
- research article
- Published by MDPI AG in Applied Sciences
- Vol. 11 (2) , 726
Abstract
Safety standard requirements must be implemented for lumbar support robots, which are mainly used for preventing low back pain (LBP) in caregivers. Usually, simulations are used to mimic actions that are not allowed for a real person. However, a comprehensive validation of a simulator in dynamic conditions has not been conducted. In this study, an ergonomic simulator is validated through forward flexion invasive experiments. The correspondence between the simulated and experimental compressive force (CF), as well as the CF obtained using two existing models about the unified angle, is investigated. The results show that the CF error between the measurements and the simulator at a flexion angle of 30 is 11.8% and is lower than those obtained for the other two models (16.8% and 20.6%). Linear regression shows that the invasive data and estimated CF are close (slope = 1) in Merryweather’s model and CF simulator but not for Potvin’s model. We evaluate the precision of the simulator by using intraclass correlation coefficient method. Merryweather’s model is moderately consistent with invasive measurements, with R–0.685 and 0.627 at 0 and 30, while the CF simulator shows good consistency with Merryweather’s model with R–0.879 and 0836 at 0 and 30.
Keywords
Funding Information
- the Japan Agency for Medical Research and Development (AMED) (JP16he1202004)
This publication has 49 references indexed in Scilit:
- Rationale, Implementation and Evaluation of Assistive Strategies for an Active Back-Support ExoskeletonFrontiers in Robotics and AI, 2018
- Global, regional, and national incidence, prevalence, and years lived with disability for 328 diseases and injuries for 195 countries, 1990–2016: a systematic analysis for the Global Burden of Disease Study 2016The Lancet, 2017
- Exoskeletons for industrial application and their potential effects on physical work loadErgonomics, 2015
- Assessment of the impact of lifting device use on low back pain and musculoskeletal injury claims among nursesOccupational and Environmental Medicine, 2013
- The effect of acute back muscle fatigue on postural control strategy in people with and without recurrent low back painEuropean Spine Journal, 2011
- An on-body personal lift augmentation device (PLAD) reduces EMG amplitude of erector spinae during lifting tasksClinical Biomechanics, 2006
- Power assist method based on Phase Sequence and muscle force condition for HALAdvanced Robotics, 2005
- Trunk muscle activation in low-back pain patients, an analysis of the literatureJournal of Electromyography and Kinesiology, 2003
- Effect of foot movement and an elastic lumbar back support on spinal loading during free-dynamic symmetric and asymmetric lifting exertionsErgonomics, 2000
- Revised NIOSH equation for the design and evaluation of manual lifting tasksErgonomics, 1993