Abstract
We hypothesized that clinical process improvement strategies can reduce frequency of motion artifacts and expiratory phase scanning in chest CT. We reviewed 826 chest CT to establish the baseline frequency. Per clinical process improvement guidelines, we brainstormed corrective measures and priority-pay-off matrix. The first intervention involved education of CT technologists, following which 795 chest CT were reviewed. For the second intervention, instructional videos on optimal breath-hold were shown to 245 adult patients just before their chest CT. Presence of motion artifacts and expiratory phase scanning was assessed. We also reviewed 311 chest CT scans belonging to a control group of patients who did not see the instructional videos. Pareto and percentage run charts were created for baseline and post-intervention data. Baseline incidence of motion artifacts and expiratory phase scanning in chest CT was 35% (292/826). There was no change in the corresponding incidence following the first intervention (36%; 283/795). Respiratory motion and expiratory phase chest CT with the second intervention decreased (8%, 20/245 patients). Instructional videos for patients (and not education and training of CT technologists) reduce the frequency of motion artifacts and expiratory phase scanning in chest CT.Keywords
This publication has 19 references indexed in Scilit:
- Videos to influence: a systematic review of effectiveness of video-based education in modifying health behaviorsJournal of Behavioral Medicine, 2012
- Preconsent Video-Assisted Instruction Improves the Comprehension and Satisfaction in Elderly Patient Visiting Pain ClinicThe Korean Journal of Pain, 2012
- Quality Initiatives: Planning, Setting Up, and Carrying Out Radiology Process Improvement ProjectsRadioGraphics, 2012
- Quality Initiatives Respiratory Instructions for CT Examinations of the Lungs: A Hands-on GuideRadioGraphics, 2008
- The Effect of Lung Volume on Nodule Size on CTAcademic Radiology, 2007
- Spanish and English Video-Assisted Informed Consent for Intravenous Contrast Administration in the Emergency Department: A Randomized Controlled TrialAnnals of Emergency Medicine, 2007
- Artifacts in CT: Recognition and AvoidanceRadioGraphics, 2004
- CT Angiography of Pulmonary Embolism: Diagnostic Criteria and Causes of MisdiagnosisRadioGraphics, 2004
- HIGH-RESOLUTION CTRadiologic Clinics of North America, 2001
- Video modelling to educate patientsJournal of Advanced Nursing, 2001