SENSE and simultaneous multislice imaging
Open Access
- 5 November 2014
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 74 (5) , 1356-1362
Abstract
Purpose: Simultaneous multislice (SMS) acquisitions play an important role in the challenge of increasing single‐shot imaging speed. We show that sensitivity encoding in two spatial dimensions (two‐dimensional sensitivity encoding [2D‐SENSE]) can be used to reconstruct SMS acquisitions with periodic but otherwise arbitrary undersampling patterns.Theory and Methods: By adopting a 3D k‐space representation of the SMS sampling process, the accelerated in‐plane and slice‐encoding directions form a 2D‐reconstruction problem that is equivalent to volumetric controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA). 2D‐SENSE does not otherwise distinguish between standard volumetric and SMS imaging with arbitrary CAIPIRINHA sampling.Results: Use of the SENSE algorithm is demonstrated for in vivo brain data obtained with blipped‐CAIPRINHA sampling in 2D SMS‐echo planar imaging (EPI) and rapid acquisition with relaxation enhancement (RARE) acquisitions as well as 3D‐EPI with various in‐plane and through‐plane acceleration factors and CAIPIRINHA shifts. The proposed SENSE reconstruction works for any combination of SMS‐factor and CAIPIRINHA shift by the addition of “dummy slices” that allow for noninteger undersampling in the slice direction. Images with commonly used slice‐generalized autocalibrating partially parallel acquisitions reconstruction are shown for reference.Conclusion: SENSE is conceptually simple and provides a one‐step reconstruction along both undersampled dimensions. It also provides a contrast‐independent parallel imaging reconstruction for SMS. Magn Reson Med 74:1356–1362, 2015.Keywords
Funding Information
- NIH (1R01 DA021146 (BRP), U54 56883 (SNRP), and K02-DA16991)
- Brains Unlimited/Scannexus (D0069)
This publication has 16 references indexed in Scilit:
- Interslice leakage artifact reduction technique for simultaneous multislice acquisitionsMagnetic Resonance in Medicine, 2013
- Blipped‐controlled aliasing in parallel imaging for simultaneous multislice echo planar imaging with reduced g‐factor penaltyMagnetic Resonance in Medicine, 2011
- Temporal SNR characteristics in segmented 3D‐EPI at 7TMagnetic Resonance in Medicine, 2011
- Multiband multislice GE‐EPI at 7 tesla, with 16‐fold acceleration using partial parallel imaging with application to high spatial and temporal whole‐brain fMRIMagnetic Resonance in Medicine, 2010
- General formulation for quantitative G‐factor calculation in GRAPPA reconstructionsMagnetic Resonance in Medicine, 2009
- Controlled aliasing in volumetric parallel imaging (2D CAIPIRINHA)Magnetic Resonance in Medicine, 2006
- Controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) for multi‐slice imagingMagnetic Resonance in Medicine, 2005
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002
- Advances in sensitivity encoding with arbitrary k‐space trajectoriesMagnetic Resonance in Medicine, 2001
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999