Abstract
The implementation of a vibration control system has always been associated with considerable capital and long-standing maintenance costs, resulting in limited practical applications of damping devices. The notion of a massive implementation cost is largely the result of a lack of cost analysis of vibration control systems in the literature. This paper presents the structural design of a wind-sensitive tall building at various design stages and the results of a collaborative study with two damper construction companies on the cost estimation of a control device. A series of wind tunnel pressure tests were conducted on a 1∶400 scale model to determine the translational and torsional wind forces acting on the studied building. A structural optimization was subsequently employed to reduce the excessive top deflection, and a smart tuned mass damper was implemented at the final design stage to meet occupant comfort criteria. The details of each structural design stage, the implementation of vibration c...

This publication has 13 references indexed in Scilit: