Effective-dose estimation in interventional radiological procedures
- 8 March 2018
- journal article
- research article
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 11 (2) , 149-155
Abstract
Interventional radiology is based on minimally invasive procedures that allow diagnosis and percutaneous treatment of diseases in almost all organ systems. Such procedures have many benefits, but they also contribute significantly to collective radiation dose. In this regard, effective dose (E) is a convenient quantity to estimate patients’ stochastic radiation risk. However, E cannot be accurately evaluated immediately. In the present study, we aimed to estimate the E value in 15 selected interventional procedures. The estimation was based on dose area product (DAP) measurements and used case-specific conversion coefficients. The E values ranged from 3.3 to 69.9 mSv, depending on the kind of procedure. This wide range was mainly due to the broad variation in DAP values, which in turn depend on the details of how the procedures are performed. This suggests that to ensure valid comparative studies and universal reference levels, all interventional procedures should be well classified.Keywords
This publication has 26 references indexed in Scilit:
- Radiation dose in neuroangiography using image noise reduction technology: a population study based on 614 patientsNeuroradiology, 2013
- Reference Levels for Patient Radiation Doses in Interventional Radiology: Proposed Initial Values for U.S. PracticeRadiology, 2009
- A study of the correlation between dose area product and effective dose in vascular radiologyRadiation Protection Dosimetry, 2008
- Obesity Is a Major Determinant of Radiation Dose in Patients Undergoing Pulmonary Vein Isolation for Atrial FibrillationJACC, 2007
- Patient and Staff Dosimetry in VertebroplastySpine, 2006
- Dose conversion coefficients for interventional proceduresRadiation Protection Dosimetry, 2005
- Patient dosimetry approaches in interventional cardiology and literature dose data reviewRadiation Protection Dosimetry, 2005
- PATIENT DOSIMETRY FOR X RAYS USED IN MEDICAL IMAGINGJournal of the ICRU, 2005
- Effective doses in angiography and interventional radiology: calculation of conversion coefficients for angiography of the lower limbsBritish Journal of Radiology, 2005
- Comparison of effective doses obtained from dose–area product and air kerma measurements in interventional radiologyBritish Journal of Radiology, 2004