Abstract
Structural and mechanical anisotropy are critical to the function of many engineered tissues. This study examined the ability of anisotropic tissue constructs to overcome contact guidance cues and remodel in response to altered mechanical loading conditions. Square tissues engineered from dermal fibroblasts and type-I collagen were uniaxially loaded to induce cell and matrix alignment. After an initial time, t*, of 5–72 h, loading was switched from the x-axis to the y-axis. Cell alignment was examined throughout the experiment until a steady state was reached. Before t*, cells spontaneously aligned in the x-direction. After t*, the strength of alignment transiently decreased then increased, and mean cell orientation transitioned from the x- to the y-direction following an exponential time course with a time constant that increased with t*. Collagen fiber orientation exhibited similar trends that could not be explained by passive kinematics alone. Structural realignment resulted in concomitant changes in biaxial tissue mechanical properties. The findings suggest that even highly aligned engineered tissue constructs retain the capacity to remodel in response to altered mechanical stimuli. This may have important functional consequences when an anisotropic engineered tissue designed in vitro is surgically implanted into a mechanically complex graft site.Keywords
This publication has 34 references indexed in Scilit:
- The effect of combined cyclic mechanical stretching and microgrooved surface topography on the behavior of fibroblastsJournal of Biomedical Materials Research Part A, 2005
- Structure and Mechanics of Healing Myocardial InfarctsAnnual Review of Biomedical Engineering, 2005
- State-of-the-art tissue engineering: From tissue engineering to organ buildingSurgery, 2005
- Anisotropic strain-dependent material properties of bovine articular cartilage in the transitional range from tension to compressionJournal of Biomechanics, 2004
- Contact guidance induced organization of extracellular matrixBiomaterials, 2004
- Isotonic biaxial loading of fibroblast-populated collagen gels: a versatile, low-cost system for the study of mechanobiologyBiomechanics and Modeling in Mechanobiology, 2002
- Modelling cardiac mechanical properties in three dimensionsPhilosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences, 2001
- Molecular responses of human dermal fibroblasts to dual cues: Contact guidance and mechanical loadCell Motility, 2000
- Cell orientation response to cyclically deformed substrates: Experimental validation of a cell modelJournal of Biomechanics, 1995
- Regulation of proliferation of fibroblasts of low and high population doubling levels grown in collagen latticesMechanisms of Ageing and Development, 1981