A k-space method for large-scale models of wave propagation in tissue
Authors:
- T.D. MastTMT.D. Mast
- L.P. SouriauLSL.P. Souriau
- D.-L.D. LiuDLD.-L.D. Liu
- M. TabeiMTM. Tabei
- A.I. NachmanANA.I. Nachman
- R.C. WaagRWR.C. Waag
- 1 March 2001
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 48 (2) , 341-354
Abstract
Large-scale simulation of ultrasonic pulse propagation in inhomogeneous tissue is important for the study of ultrasound-tissue interaction as well as for development of new imaging methods. Typical scales of interest span hundreds of wavelengths. This paper presents a simplified derivation of the k-space method for a medium of variable sound speed and density; the derivation clearly shows the relationship of this k-space method to both past k-space methods and pseudospectral methods. In the present method, the spatial differential equations are solved by a simple Fourier transform method, and temporal iteration is performed using a k-t space propagator. The temporal iteration procedure is shown to be exact for homogeneous media, unconditionally stable for "slow" (c(x)/spl les/c/sub 0/) media, and highly accurate for general weakly scattering media. The applicability of the k-space method to large-scale soft tissue modeling is shown by simulating two-dimensional propagation of an incident plane wave through several tissue-mimicking cylinders as well as a model chest wall cross section. A three-dimensional implementation of the k-space method is also employed for the example problem of propagation through a tissue-mimicking sphere. Numerical results indicate that the k-space method is accurate for large-scale soft tissue computations with much greater efficiency than that of an analogous leapfrog pseudospectral method or a 2-4 finite difference time-domain method. However, numerical results also indicate that the k-space method is less accurate than the finite-difference method for a high contrast scatterer with bone-like properties, although qualitative results can still be obtained by the k-space method with high efficiency. Possible extensions to the method, including representation of absorption effects, absorbing boundary conditions, elastic-wave propagation, and acoustic nonlinearity, are discussed.Keywords
This publication has 34 references indexed in Scilit:
- FDTD simulation of finite-amplitude pressure and temperature fields for biomedical ultrasoundThe Journal of the Acoustical Society of America, 1999
- Simulation of acoustic wave propagation in dispersive media with relaxation losses by using FDTD method with PML absorbing boundary conditionIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1999
- Erratum: “Simulation of ultrasonic pulse propagation through the abdominal wall” [J. Acoust. Soc. Am. 102, 1177–1190 (1997)]The Journal of the Acoustical Society of America, 1998
- Simulation of ultrasonic pulse propagation through the abdominal wallThe Journal of the Acoustical Society of America, 1997
- A perfectly matched layer for the absorption of electromagnetic wavesJournal of Computational Physics, 1994
- Time domain wave equations for lossy media obeying a frequency power lawThe Journal of the Acoustical Society of America, 1994
- An equation for acoustic propagation in inhomogeneous media with relaxation lossesThe Journal of the Acoustical Society of America, 1990
- Multiprocessor FFTsParallel Computing, 1987
- A nonreflecting boundary condition for discrete acoustic and elastic wave equationsGeophysics, 1985
- Numerical Analysis of Spectral Methods1977