Corrosion of Steel in Concentrated Lithium Hydroxide Solution at 316 C
Authors:
- 1 November 1962
- journal article
- Published by Association for Materials Protection and Performance (AMPP) in Corrosion
- Vol. 18 (11) , 401t-405t
Abstract
Recent laboratory work has shown that concentrated sodium hydroxide, which has been blamed for many failures in power plant operations, does in fact produce very high corrosion rates and a drastic pitting attack on steel at 316 C. It is now shown that no such attack on steel is produced by concentrated lithium hydroxide at 316 C. A mechanism accounting for some of the details of corrosion behavior of steel in concentrated lithium hydroxide is described. It is concluded that lithium hydroxide warrants consideration as an alkalizing agent in steam generating plants and on the secondary side of nuclear power reactors. 6.2.5, 4.3.3, 8.2.2, 7.11.1Keywords
This publication has 6 references indexed in Scilit:
- Corrosion of Mild Steel In 40 Percent Sodium Hydroxide Solution at 316 CCorrosion, 1962
- SOLUBILITY OF LITHIUM HYDROXIDE IN WATER AND VAPOR PRESSURE OF SOLUTIONS OF LITHIUM HYDROXIDE ABOVE 220 F1959
- Phase Transition of Li2O–Fe2O3 System. I. Thermal and Electric Properties of Lithium Ferrite LiFeO2Bulletin of the Chemical Society of Japan, 1958
- A Hydrogen Effusion Method for the Determination of Corrosion Rates in Aqueous Systems at Elevated Temperature and PressureJournal of the Electrochemical Society, 1957
- Geregelte und ungeregelte Strukturen von Titanaten und Ferriten und geregelte Umwandlungen der TiO2‐ModifikationenHelvetica Chimica Acta, 1944
- A New Type of Crystal Fine-Structure: Lithium Ferrite (O · )Physical Review B, 1931