Glucose sensor using a phospholipid polymer-based enzyme immobilization method
- 13 January 2008
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 391 (4) , 1269-1274
Abstract
An electroenzymatic glucose sensor based on a simple enzyme immobilization technique was constructed and tested. The glucose sensor measures glucose concentrations as changes of oxygen concentrations induced by enzymatic reactions. The immobilizing procedure was developed with the purpose of producing wearable biosensors for clinical use. Two types of biocompatible polymers, 2-methacryloyloxyethyl phosphorylcholine (MPC) copolymerized with dodecyl methacrylate (PMD) and MPC copolymerized with 2-ethylhexyl methacrylat, were compared as a sensitive membrane of biosensors. The PMD enzyme membrane had a better response time. Linearity, reproducibility, effect of the concentrations of immobilized enzyme and drifts of sensor characteristics in long-term tests were also investigated. The linear characteristics were confirmed with glucose concentration from 0.01 to 2.00 mmol/l, with a coefficient of determination of 0.9999. The average output current for 1 mmol/l and the standard deviation were 0.992 and 0.0283 μA. Significant changes in the sensor's characteristics were not observed for 2 weeks when it was kept in a refrigerator at 4 °C. Because of the simple procedure, the enzyme immobilization method is not only useful for wearable devices but also other devices such as micro total analysis systems.Keywords
This publication has 21 references indexed in Scilit:
- A flexible and wearable biosensor for tear glucose measurementBiomedical Microdevices, 2007
- A flexible and wearable glucose sensor based on functional polymers with Soft-MEMS techniquesBiosensors and Bioelectronics, 2006
- Biosensors for real-time in vivo measurementsBiosensors and Bioelectronics, 2005
- A Thermophilic Apoglucose Dehydrogenase as Nonconsuming Glucose SensorBiochemical and Biophysical Research Communications, 2000
- Why do phospholipid polymers reduce protein adsorption?Journal of Biomedical Materials Research, 1998
- Optical assay for glucose based on the luminescnence decay time of the long wavelength dye Cy5™Sensors and Actuators B: Chemical, 1997
- Analysis of metabolites in sweat as a measure of physical conditionAnalytica Chimica Acta, 1994
- Fully reversible fibre-optic glucose biosensor based on the intrinsic fluorescence of glucose oxidaseAnalytica Chimica Acta, 1989
- Fiber-optic biosensors based on fluorescence energy transferTalanta, 1988
- Tear glucose levels in normal people and in diabetic patients.British Journal of Ophthalmology, 1980