Pocket creation in the prepectoral subfascial position for the implantation of a cardiac implantable electrical device
Author:
- Katsuhiko ImaiKIKatsuhiko Imai
Open Access
- 4 April 2014
- journal article
- Published by Wiley in Journal of Arrhythmia
- Vol. 30 (2) , 92-94
Abstract
Pockets created in the prepectoral subcutaneous space in electrophysiology laboratories for the implantation of a cardiac implantable electrical device (CIED) have several advantages; however, lean or small subjects are thought to cause pocket erosion. To minimize such traumatic pocket complications, prepectoral subfascial implantation has been employed since the early 1990s. In this paper, we introduce a method for prepectoral subfascial pocket creation.Keywords
This publication has 9 references indexed in Scilit:
- Risk factors and time delay associated with cardiac device infections: Leiden device registryHeart, 2008
- Recognition and Correction of Subcuticular Malposition of Pacemaker Pulse GeneratorsPacing and Clinical Electrophysiology, 2001
- Long-term Follow-up of Cardioverter-Defibrillator Implanted Under Conscious Sedation in Prepectoral Subfascial PositionCirculation, 1997
- Safety of implantation of a cardioverter-defibrillator without general anesthesia in an electrophysiology laboratoryThe American Journal of Cardiology, 1995
- Technique for implantation of cardioverter defibrillators in the subpectoral positionThe Annals of Thoracic Surgery, 1995
- Electrophysiological laboratory, electrophysiologist-implanted, nonthoracotomy-implantable cardioverter/defibrillators.Circulation, 1994
- The Implantable Cardioverter Defibrillator Revolution ContinuesMayo Clinic Proceedings, 1994
- Consistent Subcutaneous Prepectoral Implantation of a New Implantable Cardioverter DefibrillatorMayo Clinic Proceedings, 1994
- Total Pectoral Implantation: A New Technique for Implantation of Transvenous Defibrillator Lead Systems and Implantable Cardioverter DefibrillatorPacing and Clinical Electrophysiology, 1993