Comparative Study of Multiphase 5-Level Cascaded H-Bridge Multilevel Inverter System
Authors:
Open Access
- 1 August 2022
- conference paper
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2312 (1) , 012062
Abstract
In terms of cost and structural design, the cascaded H-bridge multilevel inverter (CHBMLI) has a significant advantage over diode clamped and capacitor clamped multilevel inverters. The total harmonic distortion (THD) of a 5-level CHBMLI system for three different phases (single-phase, three-phase, and six-phase system) is studied and compared in this work. As switching angles play a role in lowering THD, the switching angles for a 5-level CHBMLI are evaluated using four specific switching angle methods in the initial section of this paper. In the simulation of single-phase system, these angles are being utilized. The angles with the lowest THD value are chosen for three-phase and six-phase system simulation. Based on the findings, the higher phase of 5-level CHBMLI is more efficient in decreasing harmonics.Keywords
This publication has 3 references indexed in Scilit:
- An inclusive review on different multi-level inverter topologies, their modulation and control strategies for a grid connected photo-voltaic systemSolar Energy, 2018
- Modeling of A Single Phase 7-Level Cascaded H-Bridge Multilevel InverterInternational Journal of Engineering & Technology, 2018
- A comprehensive review on reduced switch multilevel inverter topologies, modulation techniques and applicationsRenewable and Sustainable Energy Reviews, 2017