Thirty-minute compared to standardised office blood pressure measurement in general practice
Authors:
- Nynke Scherpbier-De HaanNHNynke Scherpbier-De Haan
- Mark van der WelMWMark van der Wel
- Gijs SchoenmakersGSGijs Schoenmakers
- Steve BoudewijnsSBSteve Boudewijns
- Petronella PeerPPPetronella Peer
- Chris van WeelCWChris van Weel
- Theo ThienTTTheo Thien
- Carel BakxCBCarel Bakx
Open Access
- 1 September 2011
- journal article
- research article
- Published by Royal College of General Practitioners in British Journal of General Practice
- Vol. 61 (590) , e590-e597
Abstract
Although blood pressure measurement is one of the most frequently performed measurements in clinical practice, there are concerns about its reliability. Serial, automated oscillometric blood pressure measurement has the potential to reduce measurement bias and white-coat effect'. To study agreement of 30-minute office blood pressure measurement (OBPM) with standardised OBPM, and to compare repeatability. Method comparison study in two general practices in The Netherlands. Thirty-minute and standardised OBPM was carried out with the same, validated device in 83 adult patients, and the procedure was repeated after 2 weeks. During 30-minute OBPM, blood pressure was measured automatically every 3 minutes, with the patient in a sitting position, alone in a quiet room. Agreement between 30-minute and standardised OBPM was assessed by Bland-Altman analysis. Repeatability of the blood pressure measurement methods after 2 weeks was expressed as the mean difference in combination with the standard deviation of difference (SDD). Mean 30-minute OBPM readings were 7.6/2.5 mmHg (95% confidence interval [CI] = 6.1 to 9.1/1.5 to 3.4 mmHg) lower than standardised OBPM readings. The mean difference and SDD between repeated 30-minute OBPMs (mean difference = 3/1 mmHg, 95% CI = 1 to 5/0 to 2 mmHg; SDD 9.5/5.3 mmHg) were lower than those of standardised OBPMs (mean difference = 6/2 mmHg, 95% CI = 4 to 8/1 to 4 mmHg; SDD 10.9/6.3 mmHg). Thirty-minute OBPM resulted in lower readings than standardised OBPM and had a better repeatability. These results suggest that 30-minute OBPM better reflects the patient's true blood pressure than standardised OBPM does.Keywords
This publication has 24 references indexed in Scilit:
- Conventional versus automated measurement of blood pressure in primary care patients with systolic hypertension: randomised parallel design controlled trialBMJ, 2011
- Recommendations for Blood Pressure Measurement in Humans and Experimental AnimalsCirculation, 2005
- Comparison of agreement between different measures of blood pressure in primary care and daytime ambulatory blood pressureBMJ, 2002
- Comparison of acceptability of and preferences for different methods of measuring blood pressure in primary careBMJ, 2002
- Reproducibility of home, ambulatory, and clinic blood pressure: implications for the design of trials for the assessment of antihypertensive drug efficacyAmerican Journal of Hypertension, 2002
- How should we measure blood pressure in the doctorʼs office?Blood Pressure Monitoring, 2001
- A validation of the Mobil O Graph (version 12) ambulatory blood pressure monitorBlood Pressure Monitoring, 2000
- Use and interpretation of ambulatory blood pressure monitoring: recommendations of the British Hypertension SocietyBMJ, 2000
- Reliability of Self-reported Blood Pressure MeasurementsArchives of internal medicine (1960), 1999
- Task Force V: White-coat hypertensionBlood Pressure Monitoring, 1999