Investigation on Precise Adjustment Model of the USBL Calibration Observations for Angular Misalignment

Authors:

Abstract
The angle misalignment of the ultra-short baseline system (USBL) greatly decreases its positioning precision in ocean engineering applications. The strict calibration must be performed in deep-sea surveys. This study proposes a new adjustment model for estimating the angular misalignment of a USBL system. A nonlinear Gauss-Markov model is adopted to estimate the angular misalignment and reference position of the transponder, and a two-step strategy is proposed to solve the nonlinear least-squares minimization problem. The float solution of angular misalignment and reference position of the transponder are estimated based on Kronecker product. Then the float Euler angles parameterization is fixed using a Levenberg-Marquardt algorithm. To verify the performance of the improved adjustment method, a field test was conducted in the South China Sea. Field results show that compared with the traditional calibration method, the proposed method reduces the horizontal positioning deviation from 0.69 m to 0.60 m, and the angle installation deviation from 0.29° to 0.25°.