Realization of a PEDOT:PSS/Graphene Oxide On-Chip Pseudo-Reference Electrode for Integrated ISFETs
Open Access
Abstract
A stable reference electrode (RE) plays a crucial role in the performance of an ion-sensitive field-effect transistor (ISFET) for bio/chemical sensing applications. There is a strong demand for the miniaturization of the RE for integrated sensor systems such as lab-on-a-chip (LoC) or point-of-care (PoC) applications. Out of several approaches presented so far to integrate an on-chip electrode, there exist critical limitations such as the effect of analyte composition on the electrode potential and drifts during the measurements. In this paper, we present a micro-scale solid-state pseudo-reference electrode (pRE) based on poly(3,4-ethylene dioxythiophene): poly(styrene sulfonic acid) (PEDOT:PSS) coated with graphene oxide (GO) to deploy with an ion-sensitive field-effect transistor (ISFET)-based sensor platform. The PEDOT:PSS was electropolymerized from its monomer on a micro size gold (Au) electrode and, subsequently, a thin GO layer was deposited on top. The stability of the electrical potential and the cross-sensitivity to the ionic strength of the electrolyte were investigated. The presented pRE exhibits a highly stable open circuit potential (OCP) for up to 10 h with a minimal drift of ~0.65 mV/h and low cross-sensitivity to the ionic strength of the electrolyte. pH measurements were performed using silicon nanowire field-effect transistors (SiNW-FETs), using the developed pRE to ensure good gating performance of electrolyte-gated FETs. The impact of ionic strength was investigated by measuring the transfer characteristic of a SiNW-FET in two electrolytes with different ionic strengths (1 mM and 100 mM) but the same pH. The performance of the PEDOT:PSS/GO electrode is similar to a commercial electrochemical Ag/AgCl reference electrode.Keywords
Funding Information
- Deutsche Forschungsgemeinschaft (391107823)
This publication has 49 references indexed in Scilit:
- Label-Free Biosensors Based on Aptamer-Modified Graphene Field-Effect TransistorsJournal of the American Chemical Society, 2010
- Microfabricated Reference Electrodes and their Biosensing ApplicationsSensors, 2010
- Site‐Specific Self‐Assembled Liquid‐Gated ZnO Nanowire Transistors for Sensing ApplicationsSmall, 2010
- Fabrication and application of silicon nanowire transistor arrays for biomolecular detectionSensors and Actuators B: Chemical, 2010
- Top‐down processed silicon nanowire transistor arrays for biosensingPhysica Status Solidi (a), 2009
- Miniaturised reference electrodes for field-effect sensors compatible to silicon chip technologyElectrochimica Acta, 2005
- Screen-printed reference electrodes for potentiometric measurementsAnalytica Chimica Acta, 2004
- An iridium oxide reference electrode for use in microfabricated biosensors and biochipsLab on a Chip, 2003
- Thirty years of ISFETOLOGYSensors and Actuators B: Chemical, 2003
- Nanowire Nanosensors for Highly Sensitive and Selective Detection of Biological and Chemical SpeciesScience, 2001