Gilbert damping in perpendicularly magnetized Pt/Co/Pt films investigated by all-optical pump-probe technique

Authors:

Abstract
To investigate the correlation between perpendicular magnetic anisotropy and intrinsic Gilbert damping, time-resolved magneto-optical Kerr effect was measured in Pt/Co(dCo)/Pt films. These films showed perpendicular magnetization at dCo=1.0 nm and a perpendicular magnetic anisotropy energy Kueff that was inversely proportional to dCo . With an analysis based on the Landau–Lifshitz–Gilbert equation, the intrinsic Gilbert damping constant α was evaluated by parameter-fitting of frequency and lifetime expressions to experimental data of angular variations in spin precession frequency and life-times. The α values increased significantly with decreasing dCo but not inversely proportional to dCo .

This publication has 13 references indexed in Scilit: