Porous polyurethane foams (PUR) have been extensively evaluated as meniscal replacement materials and show great promise enabling infiltration of cells and fibrocartilage formation in vivo. Similar to most materials, PUR demonstrates progressive degeneration of opposing cartilage; however, the damage mechanism is impossible to determine because no information exists on the frictional properties of PUR–cartilage interfaces. The goals of this study were to characterize the frictional behavior of a cartilage–PUR interface across a range of articulating conditions and assess the resulting morphological changes to the cartilage surface following articulation. Articular cartilage was oscillated against PUR or stainless steel using phosphate‐buffered saline (PBS) and synovial fluid as lubricants. Following friction testing, cartilage and PUR samples were analyzed with environmental scanning electron microscopy and histological staining to determine changes in tissue morphology. Stribeck‐surface analysis demonstrated distinct lubrication modes; however, boundary mode lubrication was dominant in cartilage–PUR interfaces and the low‐friction pressure‐borne lubrication mechanism present in native joints was absent. Microscopy noted obvious wear, with disruption of the collagen architecture and concomitant proteoglycan loss in cartilage articulated against PUR. These data collectively point to the importance of frictional properties as design parameters for implants and materials for soft tissue replacement. Published by Wiley Periodicals, Inc. J Orthop Res 28:1292–1299, 2010Keywords
This publication has 49 references indexed in Scilit:
- Meniscus Replacement Using Synthetic MaterialsClinics in Sports Medicine, 2009
- Comparison of cobalt chromium, ceramic and pyrocarbon hemiprostheses in a rabbit model: Ceramic leads to more cartilage damage than cobalt chromiumJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2007
- Meniscal Allografts: Biomechanics and TechniquesSports Medicine and Arthroscopy Review, 2007
- A multi-directional in vitro investigation into friction, damage and wear of innovative chondroplasty materials against articular cartilageClinical Biomechanics, 2007
- Nondegradable hydrogels for the treatment of focal cartilage defectsJournal of Biomedical Materials Research Part A, 2007
- Biomaterials and scaffold design: key to tissue‐engineering cartilageBiotechnology and Applied Biochemistry, 2007
- Friction of ceramic and metal hip hemi-endoprostheses against cadaveric acetabulaArchives of orthopaedic and trauma surgery, 2004
- Tribological evaluation of oxidized zirconium using an articular cartilage counterface: a novel material for potential use in hemiarthroplastyBiomaterials, 1997
- A model investigation of squeeze-film lubrication in animal jointsPhysics in Medicine & Biology, 1974