Wireless Single-Lead versus Standard 12-Lead ECG, for ST-Segment Deviation during Adenosine Cardiac Stress Scintigraphy
Open Access
Abstract
Wearable wireless electrocardiographic (ECG) monitoring is well-proven for arrythmia detection, but ischemia detection accuracy is not well-described. We aimed to assess the agreement of ST-segment deviation from single- versus 12-lead ECG and their accuracy for the detection of reversible ischemia. Bias and limits of agreement (LoA) were calculated between maximum deviations in ST segments from single- and 12-lead ECG during 82Rb PET-myocardial cardiac stress scintigraphy. Sensitivity and specificity for reversible anterior-lateral myocardial ischemia detection were assessed for both ECG methods, using perfusion imaging results as a reference. Out of 110 patients included, 93 were analyzed. The maximum difference between single- and 12-lead ECG was seen in II (−0.019 mV). The widest LoA was seen in V5, with an upper LoA of 0.145 mV (0.118 to 0.172) and a lower LoA of −0.155 mV (−0.182 to −0.128). Ischemia was seen in 24 patients. Single-lead and 12-lead ECG both had poor accuracy for the detection of reversible anterolateral ischemia during the test: single-lead ECG had a sensitivity of 8.3% (1.0–27.0%) and specificity of 89.9% (80.2–95.8%), and 12-lead ECG a sensitivity of 12.5% (3.0–34.4%) and a specificity of 91.3% (82.0–96.7%). In conclusion, agreement was within predefined acceptable criteria for ST deviations, and both methods had high specificity but poor sensitivity for the detection of anterolateral reversible ischemia. Additional studies must confirm these results and their clinical relevance, especially in the light of the poor sensitivity for detecting reversible anterolateral cardiac ischemia.Keywords
Funding Information
- Innovation Fund Denmark
- Novo Nordic Foundation
- Danish Cancer Society
- Steno Diabetes Center Denmark
- Copenhagen Center for Health Technology
- Radiometer, A.P. Møller Foundation
This publication has 25 references indexed in Scilit:
- Association of Postoperative High-Sensitivity Troponin Levels With Myocardial Injury and 30-Day Mortality Among Patients Undergoing Noncardiac SurgeryJAMA, 2017
- Global patient outcomes after elective surgery: prospective cohort study in 27 low-, middle- and high-income countriesBritish Journal of Anaesthesia, 2016
- Surgical outcomes in patients with chronic obstructive pulmonary disease undergoing abdominal operations: An analysis of 331,425 patientsSurgery, 2016
- Corrigendum to: '2013 ESC guidelines on the management of stable coronary artery disease'European Heart Journal, 2014
- Myocardial Injury after Noncardiac SurgeryAnesthesiology, 2014
- Pain Intensity on the First Day after SurgeryAnesthesiology, 2013
- Acute pneumonia and the cardiovascular systemThe Lancet, 2013
- Does Rubidium-82 PET Have Superior Accuracy to SPECT Perfusion Imaging for the Diagnosis of Obstructive Coronary Disease?JACC, 2012
- Characteristics and Short-Term Prognosis of Perioperative Myocardial Infarction in Patients Undergoing Noncardiac SurgeryAnnals of Internal Medicine, 2011
- Incidence and Prognosis of Unrecognized Myocardial InfarctionNew England Journal of Medicine, 1984