Bidirectional-Barbed Sutured Knotless Running Anastomosis v Classic Van Velthoven Suturing in a Model System
- 1 October 2007
- journal article
- research article
- Published by SAGE Publications in Journal of Endourology
- Vol. 21 (10) , 1175-1178
Abstract
Robotic prostatectomy is exploding into popular utilization throughout much of the United States. It is expected that the rise in the number of these cases into 2006 will continue exponentially. A significant amount of research has begun to focus on the anastomosis, because the robot allows unprecedented illumination and dexterous control to make the quality of this repair equal to that of a microscopic approach. Here, we report our results with a circular anastomosis technique using an innovative bidirectional-barbed suture material for knotless, tension-free repair and compare it with a standard polyglecaprone single-knot technique. Using a previously described in-vitro model of microfiber synthetic material, a running anastomosis was performed using the da Vinci Surgical System by one surgeon. Two pre-tied 3-0 polyglecaprone sutures on a tapered Rb-1 needle were compared with a bidirectional-barbed suture (3-0 PDO) designed specifically for our use (Quill Sutures, Research Triangle Park, NC). The times needed to perform the anastomosis, the accuracy in idealized phantoms, and the surgeon's security in the quality of his work (linear scale) were all recorded for 10 consecutive anastomoses. The PDO suture was faster to deploy (17.3 minutes v 19.2 minutes), and the security score by the surgeon was greater. The accuracy was equivalent for both types of running closure comparing the classic van Velthoven with the PDO-sutured anastomosis. It appears from our preliminary work that a bidirectional-barbed suture might improve the vesicourethral anastomosis during a robotic radical prostatectomy. Further investigations should be done to measure the disruptive force necessary to distract these sutures, whether the applied forces of the barbs are adequate for maintaining a watertight seal, and the reproducibility of our results by other surgeons. All of these investigations are in progress in our laboratory.Keywords
This publication has 8 references indexed in Scilit:
- Technique and uses for absorbable barbed suturesAesthetic Surgery Journal, 2006
- Comparison of Running and Interrupted Vesicourethral Anastomoses in a Porcine ModelJournal of Endourology, 2005
- Laparoscopic Suturing: Effect of Instrument Handling on Suture StrengthJournal of Endourology, 2005
- Vattikuti Institute Prostatectomy: TechniqueJournal of Urology, 2003
- Technique for laparoscopic running urethrovesical anastomosis:the single knot methodUrology, 2003
- Techniques in Endourology Vesicourethral Anastomosis During Laparoscopic Radical Prostatectomy: The Running Suture MethodJournal of Endourology, 2000
- Running Suturing: The Ideal Length Facilitates This TaskJournal of Endourology, 2000
- AN EXPERIMENTAL MULTIPLE BARBED SUTURE FOR THE LONG FLEXOR TENDONS OF THE PALM AND FINGERSThe Journal of Bone and Joint Surgery. British volume, 1967