A Correction Method for Wet Gas Flow Metering Using a Standard Orifice and Slotted Orifices
Open Access
Abstract
Flow measurements that utilize differential pressure meters are commonly applied in industry. In such conditions, gas flow is often accompanied by liquid condensation. For this reason, errors occur in the metering process that can be attributed to the fluctuations in continuous phase parameters in the flow. Furthermore, the occurrence of a dispersed phase results in flow disturbance and dynamic pressure pulsations. For the above reasons, new methods and tools are sought with the purpose of performing measurements of gas-liquid flows providing measurement results that can be considered as fairly accurate in the cases when flow involves a liquid phase form. The paper reports the results of a study involving measurement of wet gas flow using differential pressure flowmeters. The experiments were conducted for three constant mass air flow rates equal to 0.06, 0.078 and 0.086 kg/s. After stabilization of the air flow rates, water was fed into the pipe with flow rates in the range from 0.01 to 0.16 kg/s. The research involved a standard orifice and three types of slotted orifices with various slot arrangements and geometries. The analysis focused on the effect of orifice geometry on the flow metering results. On the basis of the results, it was found that the slotted orifice generates smaller differential pressure values compared to the standard orifice. The water mass fraction in the gas leads to overestimated results of measurements across the flowmeter. Regardless of the type of the orifice, is necessary to undertake a correction of the results. The paper proposes a method of gas mass flow correction. The results were compared with the common over-reading correction models available in the literature.Keywords
This publication has 21 references indexed in Scilit:
- Influence of the orifice shape on the local heat transfer distribution and axis switching by compressible jets impinging on flat surfaceInternational Journal of Thermal Sciences, 2016
- On cavitation occurrence in perforated platesFlow Measurement and Instrumentation, 2015
- Perforated plates for fluid management: Plate geometry effects and flow regimesInternational Journal of Thermal Sciences, 2014
- Breakup of liquid jets from non-circular orificesExperiments in Fluids, 2014
- Wet gas metering technique based on slotted orifice and swirlmeter in seriesFlow Measurement and Instrumentation, 2013
- Study on discharge coefficient of perforated orifices as a new kind of flowmeterExperimental Thermal and Fluid Science, 2013
- Orifice plate meter wet gas flow performanceFlow Measurement and Instrumentation, 2009
- Gas–liquid two phase flow measurement method based on combination instrument of turbine flowmeter and conductance sensorInternational Journal of Multiphase Flow, 2008
- Study on the metering characteristics of a slotted orifice for wet gas flowFlow Measurement and Instrumentation, 2006
- Slotted orifice flowmeterAIChE Journal, 1994