Combining tethered and untethered magnetic robots via a magnetically triggerable latch for target payload delivery and retrieval
Open Access
- 2 January 2026
- journal article
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (1) , eadu6025
Abstract
The reach and scope of minimally invasive surgical procedures can be transformed via the development of continuum robots. Through soft, flexible structures and accurate navigation, previously inaccessible anatomical regions can be safely reached. Dependent on both actuation mode and clinical application, however, rigidity and miniaturization potential can still present substantial challenges. Magnetic soft continuum robots (mSCRs) offer promising solutions to these key questions. Furthermore, micrometer- to millimeter-scale untethered magnetic robots (mUMRs) offer unparalleled miniaturization potential enabling targeted therapeutic delivery. Leveraging the benefits of magnetic actuation, this study introduces a bespoke, continuously magnetized catheter that synergizes the navigational strengths of mSCRs with the functional effectiveness of mUMRs to precisely deliver drug-doped payloads to otherwise unreachable regions deep within the anatomy. In particular, this system uses a magnetic latching mechanism, ensuring precise drug delivery and efficient retrieval, demonstrated in an ex vivo porcine kidney model for organ transplantation–related immunosuppressant delivery.Keywords
Funding Information
- Engineering and Physical Sciences Research Council (EP/V009818/1, EP/V009818/2, EP/Y037235/1)
- European Research Council (818045)
- Max Planck Society (834531)
- Max Planck Society (834531)
- University of Leeds International Strategic Fund
- ERC Proof of Concept STENTBOT project (101100727)
- ERC Proof of Concept STENTBOT project (101100727)
- University of Hawaiʻi at Mānoa (Startup Grant)
This publication has 65 references indexed in Scilit:
- Design of a Magnetic Resonance Imaging Guided Magnetically Actuated Steerable CatheterJournal of Medical Devices, 2017
- The cellular magnetic response and biocompatibility of biogenic zinc- and cobalt-doped magnetite nanoparticlesScientific Reports, 2017
- A cable-driven soft robot surgical system for cardiothoracic endoscopic surgery: preclinical tests in animalsSurgical Endoscopy, 2016
- Structured light enables biomimetic swimming and versatile locomotion of photoresponsive soft microrobotsNature Materials, 2016
- Accurate modeling and positioning of a magnetically controlled catheter tipMedical Physics, 2016
- Biopsy using a Magnetic Capsule Endoscope Carrying, Releasing, and Retrieving Untethered MicrogrippersIEEE Transactions on Biomedical Engineering, 2013
- The global role of kidney transplantationThe Lancet, 2012
- A Comparison of Laparoscopically Assisted and Open Colectomy for Colon CancerThe New England journal of medicine, 2004
- Microbubble contrast agents: a new era in ultrasoundBMJ, 2001
- Biocompatibility of new, clinically used, and recycled orthodontic samarium-cobalt magnetsAmerican Journal of Orthodontics and Dentofacial Orthopedics, 1994