Laser fluorescence detection of subgingival calculus using the DIAGNOdent Classic versus periodontal probing
Authors:
- 19 July 2016
- journal article
- research article
- Published by Springer Nature in Lasers in Medical Science
- Vol. 31 (8) , 1621-1626
Abstract
Deposits of subgingival calculus on the root surfaces of the teeth are difficult to detect with conventional methods such as tactile probing. This study compared the performance of a 655-nm wavelength laser fluorescence (LF) system (DIAGNOdent Classic with a periodontal tip) with conventional periodontal probing under defined conditions in a laboratory simulation, using an experienced examiner. Models with a total of 30 extracted teeth with varying levels of subgingival deposits scattered on their root surfaces were prepared, and silicone impression material applied to replicate periodontal soft tissues. The models were located in a phantom head, and the presence of subgingival calculus recorded at 8 points per tooth (240 sites), then the entire scoring process repeated after 1 and 2 weeks. The optimal LF threshold was determined as a fluorescence score of 7 using Receiver Operating Characteristic curves. When compared the gold standard of direct microscopic examination of roots, LF was more sensitive, specific, and accurate than tactile probing (68.3 vs. 51.7 %; 92.1 vs. 67.8; and 80.2 vs. 59.8 %, respectively), and was also more reproducible (Cohen kappa 0.60 vs. 0.39). These data support the concept of using LF as an adjunct to clinical diagnosis.Keywords
Funding Information
- Australian Dental Research Foundation
- Australian Periodontology Research Foundation
This publication has 20 references indexed in Scilit:
- Surface area and volume determination of subgingival calculus using laser fluorescenceLasers in Medical Science, 2012
- Study of validity of autofluorescence-based incipient occlusal caries detection in vitro compared to DIAGNOdent penLaser Physics, 2012
- In vitro comparison of laser fluorescence performance with visual examination for detection of occlusal caries in permanent and primary molarsLasers in Medical Science, 2008
- The Effectiveness of InGaAsP Diode Laser Radiation to Detect Subgingival Calculus as Compared to an ExplorerJournal of Periodontology, 2004
- In vivo Effectiveness of Laser Fluorescence Compared to Visual Inspection and Radiography for the Detection of Occlusal Caries in Primary TeethCaries Research, 2003
- The possibility of detecting subgingival calculus by laser-fluorescence in vitroLasers in Medical Science, 2003
- Performance of Conventional and New Methods for the Detection of Occlusal Caries in Deciduous TeethCaries Research, 2003
- Subgingival Calculus Detection With Fluorescence Induced by 655 nm InGaAsP Diode Laser RadiationJournal of Periodontology, 2002
- Immune response to Bacteroides forsythus in a murine modelOral Microbiology and Immunology, 2001
- The Effectiveness of Subgingival Scaling and Root Planing I. Clinical Detection of Residual CalculusJournal of Periodontology, 1990