Abstract
The sterilizing efficiency of a small scale direct heating UHT sterilizer has been measured using Bacillus stearothormophilus spores suspended in water and milk. A special technique was used for accurate measurement of the correct concentration of heat resistant spores in the fluid before passage through the sterilizer. The results were compared with the values calculated from the thermal death kinetics of the same spore batch measured in the laboratory, together with the residence time distribution of the liquid in the sterilizer. The two sets of data were found to compare well for a wide range of operating temperatures, confirming that the performance of a continuous sterilizer in practice could be predicted, given accurate information for the spores and the equipment.