The Dutch colon cancer screening programme as an example of adopting indirect-outcome-based analytical performance specifications using a virtual analyser concept
Open Access
- 11 September 2026
- journal article
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
Abstract
To ensure reported laboratory results are of adequate quality, it is paramount that the set analytical performance specifications (APS) are tailored to the intended uses of the measurand. For measurands with a pivotal position in the clinical pathway, APS should be set based on clinical outcome. This paper, written as a result of an outcome-based-APS-summit in Prague, gives practical guidance on how to set outcome-based APS. Two approaches are mentioned with distinct starting points of the required performance (how much clinical misclassification do we allow, and which APS fulfils that premise) or the current performance (what is the effect of the current analytical performance characteristics (APC) on how much misclassification occurs). Importantly, APS should not just be set, but also requires monitoring, which method depends on the utilization of the test in clinical practice. The laboratory can monitor APS for so-called mother-daughter systems, individual analysers or a virtual-analyser system. This paper discusses the pros and cons of these approaches. To highlight the scope of clinically consequential outcomes for which APS can be set and monitored, the Faecal Immunochemical Testing for human haemoglobin (FIT), used for the Dutch Colorectal Cancer Screening programme (CRC-Screening), is used as an example. Here, APS were based on a clinically consequential intermediate outcome, i.e. analytically induced variability in colonoscopy referral rate (±0.5 %), and implemented as a virtual analyser system, dividing the APS budget of 10 % equally across four sources of FIT variation: reagent/calibrator lot variation, sampling buffer lot variation, within-analyser variation, and between-analyser variation.Keywords
This publication has 24 references indexed in Scilit:
- Why Metrological Traceability Matters in Medical Laboratory DiagnosticsThe Journal of Applied Laboratory Medicine, 2026
- Modelling the impact of bias in fecal immunochemical testing on long-term outcomes of colorectal cancer screeningClinica Chimica Acta, 2024
- Guidelines and Recommendations for Laboratory Analysis in the Diagnosis and Management of Diabetes MellitusClinical Chemistry, 2023
- Setting analytical performance specifications using HbA1c as a model measurandClinica Chimica Acta, 2021
- Setting minimum clinical performance specifications for tests based on disease prevalence and minimum acceptable positive and negative predictive values: Practical considerations applied to COVID-19 testingClinical Biochemistry, 2021
- 2020 ESC Guidelines for the management of acute coronary syndromes in patients presenting without persistent ST-segment elevationEuropean Heart Journal, 2020
- Defining permissible limits for the combined uncertainty budget in the implementation of metrological traceabilityClinical Biochemistry, 2018
- Colorectal cancer screening: a global overview of existing programmesGut, 2015
- Using haemoglobin A1c to diagnose type 2 diabetes or to identify people at high risk of diabetesBMJ, 2014
- Evaluation of diagnostic tests for infectious diseases: general principlesNature Reviews Microbiology, 2006