Power Quality Improvement of Synchronous Generators Using an Active Power Filter
- 19 April 2018
- journal article
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 54 (5) , 4080-4090
Abstract
Active power filters (APF) are used to improve power quality and are commonly connected in parallel with the load at the point of common coupling (PCC). They are used to compensate for harmonics from nonlinear loads, for reactive power compensation and/or balancing mains currents. This paper will investigate the effect of using an APF to improve the output power quality of a simplified synchronous generator (SSG) with distorted back-EMF. A Matlab Simulink model for the SSG is built to simulate all the system, the APF and the proposed generator. Using an APF, simulation and experimental results show significant improvements in generator output current and reduced the THD in the system.Keywords
Funding Information
- Ministry of Higher Education and Scientific Research—Libya
- University of Nottingham
- Cummins Generator Technologies
This publication has 16 references indexed in Scilit:
- Novel power converter topology for three-phase four-wire hybrid power filterIET Power Electronics, 2008
- Proportional-resonant controllers and filters for grid-connected voltage-source convertersIEE Proceedings - Electric Power Applications, 2006
- Distorted and Unbalanced Systems Compensation Within Instantaneous Reactive Power FrameworkIEEE Transactions on Power Delivery, 2006
- Stationary-frame generalized integrators for current control of active power filters with zero steady-state error for current harmonics of concern under unbalanced and distorted operating conditionsIEEE Transactions on Industry Applications, 2002
- Active power filters: A reviewIEE Proceedings - Electric Power Applications, 2000
- A phase tracking system for three phase utility interface invertersIEEE Transactions on Power Electronics, 2000
- A novel approach to the design of a shunt active filter for an unbalanced three-phase four-wire system under nonsinusoidal conditionsIEEE Transactions on Power Delivery, 2000
- A control algorithm for three-phase three-wired active power filters under nonideal mains voltagesIEEE Transactions on Power Electronics, 1999
- Operation of a phase locked loop system under distorted utility conditionsIEEE Transactions on Industry Applications, 1997
- New trends in active filters for power conditioningIEEE Transactions on Industry Applications, 1996