Establishing Fully-Automated Fundus-Controlled Dark Adaptometry: A Validation and Retest-Reliability Study
Open Access
- 1 December 2023
- journal article
- research article
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 12 (12) , 18
Abstract
Purpose: The purpose of this study was to establish and validate a novel fundus-controlled dark-adaptometry method. Methods: We developed a custom dark-adaptometry software for the S-MAIA device using the open-perimetry-interface. In the validation-substudy, participants underwent dark-adaptometry testing with a comparator device (MonCvONE, 59% rhodopsin bleach, cyan and red stimuli centered at 2 degrees, 4 degrees, and 6 degrees eccentricity). Following a brief break (approximately 5 minutes), the participants were bleached again and underwent dark-adaptometry testing with the S-MAIA device (same loci). In the retest reliability-substudy, participants were tested twice with the S-MAIA device (same loci as above). Nonlinear curve fitting was applied to extract dark-adaptation curve parameters. Validity and repeatability were summarized in terms of the mean bias and 95% limits of agreement (LoAs). Results: In the validation-substudy (N = 20 participants, median age interquartile range [IQR] 31.5 years [IQR = 25.8, 62.0]), measures of rod-mediated dark-adaptation showed little to no between method differences for the cone-rod-break-time (bias 95% confidence interval [95% CI] of +0.1 minutes [95% CI = −0.6 to 0.8]), rod-intercept-time (−0.23 minutes [95% CI = −1.38 to 0.93]), and S2 slope (−0.01 LogUnits/minutes [95% CI = −0.02 to −0.01]). In the retest reliability-substudy (N = 10 participants, 32.0 years [95% CI = 27.0, 57.5]), the corresponding LoAs were (cone-rod-break-time) −3.94 to 2.78 minutes, (rod-intercept-time) −4.55 to 3.11 minutes, and (S2 slope [rate-limited component of rod recovery]) −0.03 to 0.03 LogUnits/minutes. The LoAs for the steady-state cone and rod thresholds were −0.28 to 0.33 LogUnits and −0.34 to 0.28 LogUnits. Conclusions: The devised fundus-controlled dark-adaptometry method yields valid and reliable results. Translational Relevance: Fundus-controlled dark-adaptometry solves the critical need for localized testing of the visual cycle and retinoid transfer in eyes with unstable fixation.Keywords
All Related Versions
This publication has 45 references indexed in Scilit:
- Retinal specific measurement of dark-adapted visual function: validation of a modified microperimeterBMC Ophthalmology, 2011
- Human gene therapy for RPE65 isomerase deficiency activates the retinoid cycle of vision but with slow rod kineticsProceedings of the National Academy of Sciences, 2008
- Effect of Short-Term, High-Dose Retinol on Dark Adaptation in Aging and Early Age-Related MaculopathyInvestigative Ophthalmology & Visual Science, 2006
- Aging and dark adaptationVision Research, 1999
- Light adaptation and dark adaptation of human rod photoreceptors measured from the a‐wave of the electroretinogramThe Journal of Physiology, 1999
- Night blindness in Sorsby's fundus dystrophy reversed by vitamin ANature Genetics, 1995
- Symptomatic abnormalities of dark adaptation in patients with age-related Bruch's membrane change.British Journal of Ophthalmology, 1993
- The Effect of Light Adaptation on Scotopic Spatial Summation in 10-Week-old InfantsVision Research, 1992
- Human photoreceptor topographyJournal of Comparative Neurology, 1990
- Increment thresholds with various low background intensities at different locations in the peripheral retinaJournal of the Optical Society of America, 1983