Gastrointestinal Bleeding in Patients with Ventricular Assist Devices Is Highest Immediately After Implantation
Authors:
- Joshua B. FrenchJFJoshua B. French
- Salpy V. PamboukianSPSalpy V. Pamboukian
- James F. GeorgeJGJames F. George
- George B. SmallfieldGSGeorge B. Smallfield
- Jose A. TallajJTJose A. Tallaj
- Robert N. BrownRBRobert N. Brown
- Melissa C. SmallfieldMSMelissa C. Smallfield
- James K. KirklinJKJames K. Kirklin
- William L. HolmanWHWilliam L. Holman
- Shajan PeterSPShajan Peter
- 1 September 2013
- journal article
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 59 (5) , 480-485
Abstract
Ventricular assist device implantation is associated with gastrointestinal bleeding (GIB); however, outcomes in terms of initial and repeat GIB risk, severity, location of lesions, and endoscopic interventions need to be better defined. Consecutive patients from a database of adult patients with ventricular assist devices (VADs) implanted between January 1, 2000, and December 31, 2010, at a single center were reviewed and followed through May 31, 2011, in a retrospective manner. The GIB events were further classified by severity, lesion location, and lesion type. Hazard analysis models were calculated for the time to GIB events. Of 166 patients with a VAD, 38 patients experienced 84 GIB events. Seventeen patients experienced ≥2 GIB events. Maximal hazard for the first bleeding event was 2.23 events/patient-year at 21 days and declined to the constant hazard by 71 days postimplantation. The hazard for recurrent GIB was greatest immediately after the first GIB event. When considering all GIB events, most lesions (68%) were located in the proximal bowel. Angiodysplasia was the most common lesion type (17.5%) seen on endoscopy when all GIB events were considered, whereas ulcers were the most common type (13.8%) seen in initial GIB events. The actuarial risk of initial GIB events peaks in the first 3 months after VAD implantation followed by a stable lower risk of bleeding. The hazard for recurrent GIB events is substantially increased immediately after the initial GIB.Keywords
This publication has 22 references indexed in Scilit:
- Mechanisms of Bleeding and Approach to Patients With Axial-Flow Left Ventricular Assist DevicesCirculation: Heart Failure, 2011
- Endoscopic Findings and Clinical Outcomes in Ventricular Assist Device Recipients with Gastrointestinal BleedingDigestive Diseases and Sciences, 2011
- Management Options to Treat Gastrointestinal Bleeding in Patients Supported on Rotary Left Ventricular Assist Devices: A Single‐Center ExperienceArtificial Organs, 2010
- Increased Incidence of Gastrointestinal Bleeding Following Implantation of the HeartMate II LVADJournal of Cardiac Surgery, 2010
- Advanced Heart Failure Treated with Continuous-Flow Left Ventricular Assist DeviceThe New England journal of medicine, 2009
- Incidence and Patterns of Adverse Event Onset During the First 60 Days After Ventricular Assist Device ImplantationThe Annals of Thoracic Surgery, 2009
- Lower Gastrointestinal Bleeding Diagnosed by Red Blood Cell Scintigraphy in a Patient With a Left Ventricular Assist DeviceClinical Nuclear Medicine, 2008
- Use of a Continuous-Flow Device in Patients Awaiting Heart TransplantationNew England Journal of Medicine, 2007
- The Decomposition of Time-Varying Hazard into Phases, Each Incorporating a Separate Stream of Concomitant InformationJournal of the American Statistical Association, 1986
- Aortic stenosis associated with gastrointestinal bleeding. A survey of 612 patientsAmerican Heart Journal, 1980