The need for a readily available, inexpensive, non-invasive method for improved risk stratification of heart failure (HF) patients is paramount. Prior studies have proposed that distinct fluctuation patterns underlying the variability of physiological signals have unique prognostic value. We tested this hypothesis in an extensively phenotyped cohort of HF patients using EntropyXQT, a novel non-linear measure of cardiac repolarization dynamics. In a prospective, multicentre, observational study of 852 patients in sinus rhythm undergoing clinically indicated primary prevention implantable cardioverter-defibrillator (ICD) implantation (2003–10), exposures included demographics, history, physical examination, medications, laboratory results, serum biomarkers, ejection fraction, conventional electrocardiographic (ECG) analyses of heart rate and QT variability, and EntropyXQT. The primary outcome was first ‘appropriate’ ICD shock for ventricular arrhythmias. The secondary outcome was composite events (appropriate ICD shock and all-cause mortality). After exclusions, the cohort (n = 816) had a mean age of 60 ± 13 years, 28% women, 36% African Americans, 56% ischaemic cardiomyopathy, and 29 ± 16% Seattle HF risk score (SHFS) 5-year predicted mortality. Over 45 ± 24 months, there were 134 appropriate shocks and 166 deaths. After adjusting for 30 exposures, the hazard ratios (comparing the 5th to 1st quintile of EntropyXQT) for primary and secondary outcomes were 3.29 (95% CI 1.74–6.21) and 2.28 (1.53–3.41), respectively. Addition of EntropyXQT to a model comprised of the exposures or SHFS significantly increased net reclassification and the ROC curve area. EntropyXQT measured during ICD implantation strongly and independently predicts appropriate shock and all-cause mortality over follow-up. EntropyXQT complements conventional risk predictors and has the potential for broad clinical application.Keywords
Funding Information
- Johns Hopkins University
- NIH (HL R01 103946, HL R01 091062)
- NIH (HL R01 103946, HL R01 091062)
This publication has 39 references indexed in Scilit:
- Prospective Observational Study of Implantable Cardioverter‐Defibrillators in Primary Prevention of Sudden Cardiac Death: Study Design and Cohort DescriptionJournal of the American Heart Association, 2013
- Mortality Reduction by Heart Rate Characteristic Monitoring in Very Low Birth Weight Neonates: A Randomized TrialThe Journal of Pediatrics, 2011
- Utility of the Seattle Heart Failure Model in Patients With Advanced Heart FailureJACC, 2009
- The Seattle Heart Failure ModelCirculation, 2006
- Preserved heart rate variability identifies low-risk patients with nonischemic dilated cardiomyopathy: Results from the DEFINITE trialHeart Rhythm, 2006
- Renyi Entropy Measures of Heart Rate GaussianityIEEE Transactions on Biomedical Engineering, 2005
- Long-Term Clinical Course of Patients After Termination of Ventricular Tachyarrhythmia by an Implanted DefibrillatorCirculation, 2004
- Fractal analysis of heart rate dynamics as a predictor of mortality in patients with depressed left ventricular function after acute myocardial infarctionThe American Journal of Cardiology, 1999
- The Analysis of VariabilityJournal of Cardiovascular Electrophysiology, 1994
- Fractal Electrodynamics of the HeartbeataAnnals of the New York Academy of Sciences, 1990