A microfluidic chip based sequential injection system with trapped droplet liquid–liquid extraction and chemiluminescence detection
Authors:
- 31 July 2006
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 6 (10) , 1387-1389
Abstract
A microfluidic chip-based sequential injection system with trapped droplet liquid–liquid extraction preconcentration and chemiluminescence detection was developed for achieving high sensitivity with low reagent and sample consumption. The microfabricated glass lab-chip had a 35 mm long extraction channel, with 134 shrunken opening rectangular recesses (L 100 µm × W 50 µm × D 25 µm) arrayed within a 1 mm length on both sides of the middle section of the channel. Ketonic peroxyoxalate ester solution was filled in the recesses forming organic droplets, and keeping the aqueous sample solution flowing continuously in the extraction channel; analytes were transferred from the aqueous phase into the droplets through molecular diffusion. After liquid–liquid extraction preconcentration, catalyst and hydrogen peroxide solutions were introduced into the channel, and mixed with analytes and peroxyoxalate ester to emit chemiluminescence light. The performance of the system was tested using butyl rhodamine B, yielding a precision of 4% RSD (n = 5) and a detection limit of 10−9 M. Within a 17 min analytical cycle, the consumptions of sample and peroxyoxalate solutions were 2.7 µL and 160 nL, respectively.Keywords
This publication has 20 references indexed in Scilit:
- Microfluidic Sequential Injection Analysis in a Short CapillaryAnalytical Chemistry, 2006
- Microfluidic chip-based liquid–liquid extraction and preconcentration using a subnanoliter-droplet trapping techniqueLab on a Chip, 2005
- High-Throughput Nanoliter Sample Introduction Microfluidic Chip-Based Flow Injection Analysis System with Gravity-Driven FlowsAnalytical Chemistry, 2005
- Bonding of Glass Microfluidic Chips at Room TemperaturesAnalytical Chemistry, 2004
- Miniaturized capillary electrophoresis system with ultraviolet photometric detection combined with flow injection sample introduction using a modified falling-drop interfaceAnalytica Chimica Acta, 2004
- On-Chip Integration of Neutral Ionophore-Based Ion Pair Extraction ReactionAnalytical Chemistry, 2001
- Influence of Imidazole and Bis(trichlorophenyl) Oxalate in the Oxalyldiimidazole Peroxyoxalate Chemiluminescence ReactionAnalytical Chemistry, 1997
- Zero-Dead-Volume Peroxyoxalate Chemiluminescence Detection in Liquid ChromatographyAnalytical Chemistry, 1995
- Analytical applications of peroxyoxalate chemiluminescenceAnalytica Chimica Acta, 1978
- A Study of Chemiluminescence from Reactions of Oxalyl Chloride, Hydrogen Peroxide, and Fluorescent Compounds1Journal of the American Chemical Society, 1966