In vitro assessment of Function Graded (FG) artificial Hip joint stem in terms of bone/cement stresses: 3D Finite Element (FE) study
Open Access
- 1 January 2013
- journal article
- research article
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 12 (1) , 5
Abstract
Stress shielding in the cemented hip prosthesis occurs due to the mismatching in the mechanical properties of metallic stem and bone. This mismatching in properties is considered as one of the main reasons for implant loosening. Therefore, a new stem material in orthopedic surgery is still required. In the present study, 3D finite element modeling is used for evaluating the artificial hip joint stem that is made of Function Graded (FG) material in terms of joint stress distributions and stem length. 3D finite element models of different stems made of two types of FG materials and traditional stems made of Cobalt Chromium alloy (CoCrMo) and Titanium alloy (Ti) were developed using the ANSYS Code. The effects on the total artificial hip joint stresses (Shear stress and Von Mises stresses at bone cement, Von Mises stresses at bone and stem) due to using the proposed FG materials stems were investigated. The effects on the total artificial hip joint system stresses due to using different stem lengths were investigated. Using FG stem (with low stiffness at stem distal end and high stiffness at its proximal end) resulted in a significant reduction in shear stress at the bone cement/stem interface. Also, the Von Mises stresses at the bone cement and stem decrease significantly when using FG material instead of CoCrMo and Ti alloy. The stresses’ distribution along the bone cement length when using FG material was found to be more uniform along the whole bone cement compared with other stem materials. These more uniform stresses will help in the reduction of the artificial hip joint loosening rate and improve its short and long term performance. FE results showed that using FG stem increases the resultant stresses at the femur bone (reduces stress shielding) compared to metallic stem. The results showed that the stem length has significant effects on the resultant shear and Von Mises stresses at bone, stem and bone cement for all types of stem materials.Keywords
This publication has 29 references indexed in Scilit:
- Design and manufacturing of femoral stems for the Indian populationJournal of Manufacturing Processes, 2012
- Influences of Prosthesis Stem Lengths in Cementless Total Hip ArthroplastyApplied Mechanics and Materials, 2011
- Design and fabrication of CoCrMo alloy based novel structures for load bearing implants using laser engineered net shapingMaterials Science and Engineering: C, 2010
- A Novel Fabrication Method for Functionally Graded Materials under Centrifugal Force: The Centrifugal Mixed-Powder MethodMaterials, 2009
- Probabilistic design of a newly designed cemented hip prosthesis using finite element methodMaterials & Design (1980-2015), 2008
- Fatigue failure analysis of a specific total hip prosthesis stem designInternational Journal of Fatigue, 2008
- Properties of an injectable low modulus PMMA bone cement for osteoporotic boneJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2008
- Hip implants VII: Finite element analysis and optimization of cross-sectionsMaterials & Design (1980-2015), 2008
- Influence of changes in stem positioning on femoral loading after THR using a short-stemmed hip implantClinical Biomechanics, 2007
- Improved design of cementless hip stems using two‐dimensional functionally graded materialsJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2006