Detection of triglyceride using an iridium nano-particle catalyst based amperometric biosensor
Authors:
- 19 September 2008
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 133 (12) , 1757-1763
Abstract
The detection and quantification of triglyceride (TG) using an iridium nano-particle modified carbon based biosensor was successfully carried out in this study. The detection procedures were based on the electrochemical detection of enzymatically produced NADH. TG was hydrolyzed by lipase and the glycerol produced was catalytically oxidized by NAD-dependent glycerol dehydrogenase producing NADH in a solution containing NAD+ . Glyceryl tributyrate, a short chain triglyceride, was chosen as the substrate for the evaluation of this TG biosensor in bovine serum and human serum. A linear response to glyceryl tributyrate in the concentration range of 0 to 10 mM and a sensitivity of 7.5 nA mM−1 in bovine serum and 7.0 nA mM−1 in human serum were observed experimentally. The potential interference of species such as uric acid (UA) and ascorbic acid (AA) was assessed. The incorporation of a selected surfactant and an increase in the incubation temperature appeared to enhance the performance of this biosensor. The conditions for the determination of TG levels in bovine serum using this biosensor were optimized, with sunflower seed oil being used as an analyte to simulate the detection of TG in blood. The experimental results demonstrated that this iridium nano-particle modified working electrode based biosensor provided a relatively simple means for the accurate determination of TG in serum.Keywords
This publication has 37 references indexed in Scilit:
- Triglycerides and Risk for Coronary Heart DiseaseJAMA, 2007
- Nonfasting Triglycerides and Risk of Myocardial Infarction, Ischemic Heart Disease, and Death in Men and WomenJAMA, 2007
- Flow-injection enzymatic analysis for glycerol and triacylglycerolAnalytical Biochemistry, 2005
- The inflammation: Lipoprotein cycleAtherosclerosis Supplements, 2005
- Amperometric Measurement of Creatine Kinase Activity Using an ADP-sensing Bienzyme ElectrodeElectrochemistry, 2003
- Interfacial Enzyme Kinetics at the Phospholipid/ Water Interface: Practical ConsiderationsAnalytical Biochemistry, 2000
- Glucose Biosensor Prepared by the Deposition of Iridium and Glucose Oxidase on Glassy Carbon TransducerElectroanalysis, 1999
- Amperometric glyceride biosensorAnalytica Chimica Acta, 1996
- Electrocatalytic oxidation of NADH at poly(metallophthalocyanine)-modified electrodesJournal of Electroanalytical Chemistry, 1994
- Oxidation of NADH by oxometalatesJournal of Electroanalytical Chemistry, 1994