Commissioning and optimization of superconducting undulator in the horizontal state
Open Access
- 21 February 2024
- journal article
- research article
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 27 (2) , 022401
Abstract
Taking advantage of a higher field than a conventional permanent magnet undulator, superconducting undulators (SCUs) have been rapidly developed in recent years for applications at synchrotron radiation sources and free-electron lasers. The Institute of High Energy Physics, Chinese Academy of Sciences, has developed a 1.5-m long planar SCU with a short period of 15 mm. This SCU has been commissioned and optimized in the horizontal position. In contrast to the vertical position, where the undulator coils are immersed in liquid helium for superconductivity, the horizontal test requires the assembly of the complete device, including the cryostat, current conductor, cryocooler, vacuum chamber, and undulator coils. This test reflects the operation status and measures the SCU’s characteristics under working conditions. Although experiences from the vertical test provided good guidance for horizontal optimization, special care needs to be taken for effects such as gravity. After improving field uniformity through iterative measurements, the rms phase error of the SCU is reduced to 7.3° at a current of 400 A. Additionally, the functions of the end correction coils to mitigate field integral errors have been verified. This paper also demonstrates and analyzes other phenomena and interesting observations during the commissioning process. It discusses important issues that impact field quality and measurement accuracy and suggests further improvement measures for an even better field. Published by the American Physical Society 2024Keywords
Funding Information
- Chinese Academy of Sciences (E029A5M111)
- National Natural Science Foundation of China (12205318)
- Chinese Academy of Sciences (E029A5M111)
- National Natural Science Foundation of China (12205318)
This publication has 12 references indexed in Scilit:
- Design, construction, and magnetic field characterization of a Segmented Adaptive-Gap In-Vacuum Undulator prototype for NSLS-IIJournal of Physics: Conference Series, 2022
- Vertical measurement and on-line correction of the magnetic field for a 1.5-m-long superconducting undulatorNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2022
- Review and prospects of world-wide superconducting undulator development for synchrotrons and FELsSuperconductor Science and Technology, 2022
- Undulator design for a laser-plasma-based free-electron-laserPhysics Reports, 2021
- Universal representation of undulator phase errorsPhysical Review Accelerators and Beams, 2018
- Cryogenic permanent magnet and superconducting undulatorsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2018
- Development and operating experience of a 1.1-m-long superconducting undulator at the Advanced Photon SourcePhysical Review Accelerators and Beams, 2017
- Radiation-induced magnetization reversal causing a large flux loss in undulator permanent magnetsScientific Reports, 2016
- Overview of the superconducting undulator development program at ANKAAIP Conference Proceedings, 2016
- Nd2Fe14B and Pr2Fe14B magnets characterisation and modelling for cryogenic permanent magnet undulator applicationsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2012