Three-Month Safety and Efficacy Outcomes for the Smaller-Incision New-Generation Implantable Miniature Telescope (SING IMT™)
Open Access
- 8 January 2023
- journal article
- research article
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (2) , 518
Abstract
The smaller-incision new-generation implantable miniature telescope (SING IMT™) is the second generation of the IMT™, a telescope prosthesis that is indicated for monocular implantation in patients with stable vision impairment caused by bilateral central scotomas associated with end-stage Age-related macular degeneration (AMD). This non-comparative retrospective study is the first and largest single-surgeon case series to evaluate the short-term (3 months) safety and efficacy of the device in patients with disciform scars or geographic atrophy at baseline. The main outcome measures included best-corrected distance and near visual acuity (CDVA and CDNVA, respectively), endothelial cell density (ECD) loss, and the incidence of complications. At postoperative month 3 in the study eyes, mean CDVA and CDNVA improved by +14.9 ± 7.1 letters and +7.7 ± 3.2 Jaeger levels, respectively. Importantly, 70.83% of patients gained ≥ 2 lines, 58.33% ≥ 3 lines, and 25.00% ≥ 4 lines of CDVA. From baseline, ECD loss in the study eyes was 10.4 ± 13.3% at 3 months, however, ECD was comparable between the study and fellow eyes at all time points. The most common complication was corneal edema. In all, these short-term outcomes suggest that the SING IMT™ delivers lower ECD loss than the first-generation IMT ™, but similar visual outcomes and safety.Keywords
Funding Information
- Department of Ophthalmology, University of Naples Federico II
This publication has 26 references indexed in Scilit:
- Improving quality of life in patients with end-stage age-related macular degeneration: focus on miniature ocular implantsClinical Ophthalmology, 2011
- Change in Area of Geographic Atrophy in the Age-Related Eye Disease StudyArchives of Ophthalmology (1950), 2009
- Implantable Telescope for End-Stage Age-related Macular Degeneration: Long-term Visual Acuity and Safety OutcomesAmerican Journal of Ophthalmology, 2008
- Cataract Surgery and the 10-Year Incidence of Age-Related MaculopathyOphthalmology, 2006
- Implantable Miniature Telescope for the Treatment of Visual Acuity Loss Resulting from End-Stage Age-Related Macular Degeneration: 1-Year ResultsOphthalmology, 2006
- Age‐related macular degeneration—emerging pathogenetic and therapeutic conceptsAnnals of Medicine, 2006
- A prospective multicenter clinical trial to evaluate the safety and effectiveness of the implantable miniature telescopeAmerican Journal of Ophthalmology, 2004
- Cataract surgery and the 5-year incidence of late-stage age-related maculopathyOphthalmology, 2003
- Age-related Macular Degeneration after Extracapsular Cataract Extraction with Intraocular Lens ImplantationOphthalmology, 1996
- Continued Endothelial Cell Loss Ten Years after Lens ImplantationOphthalmology, 1994