Power electronic transformer (PET) converter: Design of a 1.2MW demonstrator for traction applications
Authors:
- 1 June 2012
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 855-860
Abstract
A power electronic transformer converter made of cascaded multiple cells with a medium frequency link can replace the bulky traditional transformer in various applications with several advantages, including reduced size and weight, and energy savings. This paper describes the design of a 1.2MW power electronic transformer (PET) demonstrator for traction applications. Several design challenges, i.e. the selection of the IGBT modules, the design of the multiple-functional medium frequency transformer, and the mechanical arrangement to achieve the high voltage insulation between the grid voltage and ground potential, have been discussed. The experimental results, obtained from the developed PET demonstrator, are presented.Keywords
This publication has 5 references indexed in Scilit:
- New power technologies for traction drives2010
- AC/DC converter with medium frequency link for railway traction application. Evaluation of semiconductor losses and operating limits.2010
- High voltage IGBTs and medium frequency transformer in DC-DC converters for railway applications2010
- Medium frequency topology in railway applications2007
- Power electronics traction transformer2007