Hearing Preservation Via a Cochleostomy Approach and Deep Insertion of a Standard Length Cochlear Implant Electrode
Authors:
- Iain Alexander BruceIBIain Alexander Bruce
- James Edward Homewood Mills BatesJBJames Edward Homewood Mills Bates
- Christine MellingCMChristine Melling
- Deborah MawmanDMDeborah Mawman
- Kevin Michael John GreenKGKevin Michael John Green
- 1 December 2011
- journal article
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 32 (9) , 1444-1447
Abstract
The suggestion that the depth of insertion of the electrode into the cochlea is critical to hearing preservation has led to the development of a generation of short electrodes designed to minimize intracochlear trauma and avoid contact with the apical region of the cochlea. This study aims to describe our experience of hearing preservation surgery using a deeply inserted standard length electrode array covering the region of residual hearing. A retrospective case note review was performed identifying cases of attempted hearing preservation using standard length electrodes. Study based at Manchester Royal Infirmary, a tertiary referral center. Fourteen cochlear implants in 13 patients were identified for further analysis from the Manchester Cochlear Implant Programme database. Each patient received the same design of implant using a "soft" surgical technique. Preoperative and postoperative air conduction thresholds were compared to assess the degree of hearing preservation. Successful hearing preservation was demonstrated in 12 of 14 cases, and the postoperative residual hearing thresholds in 3 adolescents receiving a standard length electrode array were found to have improved. Preservation of speech recognition was not measured in this study, rather hearing was tested by pure tone audiogram. Follow-up at the time of this study ranged from 1 week to 23 months. This study demonstrates that deep insertion of the electrode into the cochlea does not preclude successful hearing preservation. It also highlights that residual hearing can be consistently preserved using a "cochleostomy" approach.Keywords
This publication has 5 references indexed in Scilit:
- Partial Deafness Cochlear Implantation at the University of Kansas: Techniques and OutcomesJournal of the American Academy of Audiology, 2010
- Results of Partial Deafness Cochlear Implantation Using Various Electrode DesignsAudiology and Neurotology, 2009
- Outcomes in adults implanted with the FLEX
soft
electrodeActa Oto-Laryngologica, 2007
- Representation of acoustic signals in the human cochlea in presence of a cochlear implant electrodeHearing Research, 2006
- Preservation of Residual Hearing in Children and Post-Lingually Deafened Adults after Cochlear Implantation: An Initial StudyORL, 2002