Glaucoma management in Boston keratoprosthesis type I recipients
Authors:
- Vikas ChopraVCVikas Chopra
- 1 March 2014
- journal article
- review article
- Published by Wolters Kluwer Health in Current Opinion in Ophthalmology
- Vol. 25 (2) , 134-140
Abstract
To review the literature on management of glaucoma in Boston keratoprosthesis type I recipients. Glaucoma is a prevalent and important cause of permanent loss of sight in Boston keratoprosthesis recipients. The management of glaucoma is challenging as there are no reliable and accurate means to monitor the intraocular pressure (IOP) in these patients, and no standardized protocols exist regarding management. Because a significant number of patients require glaucoma drainage device placement, further studies are needed to determine ways to reduce the risk of shunt-associated complications. Surgical adjustments including posterior shunt placement, adjunctive corneal patch graft, and selection of a different size bandage contact lens can help reduce shunt-associated complications. Anterior segment optical coherence tomography is useful in elucidating the mechanisms of failure to control IOP. Continual innovations in imaging and IOP measurement technologies will assist surgeons' preoperative planning and postoperative management. In keratoprosthesis recipients, glaucoma often leads to permanent loss of sight. It is imperative that these patients be monitored with vigilance by a multidisciplinary team to prevent progression. Pooled data from multiple centers and technologic innovations will assist the surgeon to design a surgical approach and postoperative management regimen for the individual recipient.Keywords
This publication has 45 references indexed in Scilit:
- High-Resolution Spectral Domain Anterior Segment Optical Coherence Tomography in Type 1 Boston KeratoprosthesisCornea, 2013
- Glaucoma therapy and ocular surface diseaseCurrent Opinion in Ophthalmology, 2013
- POSTOPERATIVE POSTERIOR SEGMENT COMPLICATIONS IN EYES TREATED WITH THE BOSTON TYPE I KERATOPROSTHESISRetina, 2013
- Glaucoma Associated With Boston Type I KeratoprosthesisCornea, 2012
- Polymer-based miniature flexible capacitive pressure sensor for intraocular pressure (IOP) monitoring inside a mouse eyeBiomedical Microdevices, 2011
- Long-term Complications Associated with Glaucoma Drainage Devices and Boston KeratoprosthesisAmerican Journal of Ophthalmology, 2011
- Toxicological evaluation of preservative-containing and preservative-free topical prostaglandin analogues on a three-dimensional-reconstituted corneal epithelium systemBritish Journal of Ophthalmology, 2011
- Evaluation of agreement between intraocular pressure measurements using Goldmann applanation tonometry and Goldmann correlated intraocular pressure by Reichert's ocular response analyserEye, 2010
- Optical Functional Properties of the Boston KeratoprosthesisInvestigative Ophthalmology & Visual Science, 2010
- Conjunctival and corneal reactions in rabbits following short- and repeated exposure to preservative-free tafluprost, commercially available latanoprost and 0.02% benzalkonium chlorideBritish Journal of Ophthalmology, 2008