A simple approach in balancing the slider-crank mechanisms applied to new systems
Authors:
Open Access
- 4 June 2025
- journal article
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 19546
Abstract
This study presents a simple method for balancing a slider-crank mechanism which is applied to a new system. A counterweight is designed and located on the crank link to solve the vibration of slider-crank mechanism. The calculation of counterweight design is proposed to balance the single and double slider-crank mechanisms which are exploited to develop the fast scanning module of scanning acoustic microscopy (SAM) system. Based on the ultrasound characteristics, SAM system can provide the internal image with high resolution up to several tens of micrometers. Following that, the counterweight is optimized to minimize the shaking force acting on the ground frame, resulting in vibration reduction of the SAM system. The equations of shaking force are defined, which are simulated to find out the shape and size of suitable counterweight. Based on the simulation results, counterweights were designed and fabricated, which were used for single and double slider-crank mechanisms of two SAM systems. By interpreting the scanning images provided by SAM systems, the dimensions of specimen are measured at minimum and maximum values that are used to validate the counterweight calculation. Finally, the design process flowchart of counterweight is proposed for balancing slider-crank mechanism, which can be used to extend the mechanism application in many fields.Keywords
This publication has 17 references indexed in Scilit:
- Novel Water Probe for High-Frequency Focused Transducer Applied to Scanning Acoustic Microscopy System: Simulation and Experimental InvestigationSensors, 2024
- Development of fast scanning module with a novel bubble solution applied to scanning acoustic microscopy system for industrial nondestructive inspectionExpert Systems with Applications, 2023
- Development of fast photoacoustic and ultrasound imaging system based on slider-crank scanner for small animals and humans studyExpert Systems with Applications, 2022
- Ultra-widefield photoacoustic microscopy with a dual-channel slider-crank laser-scanning apparatus for in vivo biomedical studyPhotoacoustics, 2021
- A Comprehensive Examination of High-Temperature Hydrogen Attack—A Review of over a Century of InvestigationsJournal of Materials Engineering and Performance, 2021
- High resolution ply-by-ply ultrasound imaging of impact damage in thick CFRP laminates by high-frequency acoustic microscopyComposite Structures, 2021
- Combined surface-focused acoustic microscopy in transmission and scanning ultrasonic holographyUltrasonics, 2006
- Complete balancing of planar linkages by an equivalence methodMechanism and Machine Theory, 1994
- Complete shaking force and shaking moment balancing of 26 types of four-, five- and six-bar linkages with prismatic pairsMechanism and Machine Theory, 1990
- An approximate method of calculating a counterweight for the balancing of vertical inertia forcesJournal of Mechanisms, 1968