Mechanical Versus Manual Ventilation via a Face Mask During the Induction of Anesthesia: A Prospective, Randomized, Crossover Study
Authors:
- Achim Von GoedeckeAGAchim Von Goedecke
- Wolfgang G VoelckelWVWolfgang G Voelckel
- Volker WenzelVWVolker Wenzel
- Christoph HörmannCHChristoph Hörmann
- Horst G Wagner-BergerHWHorst G Wagner-Berger
- Volker DörgesVDVolker Dörges
- Karl H LindnerKLKarl H Lindner
- Christian KellerCKChristian Keller
- 1 January 2004
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 98 (1) , 260-263
Abstract
One approach to make ventilation safer in an unprotected airway has been to limit tidal volumes; another one might be to limit peak airway pressure, although it is unknown whether adequate tidal volumes can be delivered. Accordingly, the purpose of this study was to evaluate the quality of automatic pressure-controlled ventilation versus manual circle system face-mask ventilation regarding ventilatory variables in an unprotected airway. We studied 41 adults (ASA status I–II) in a prospective, randomized, crossover design with both devices during the induction of anesthesia. Respiratory variables were measured with a pulmonary monitor (CP-100). Pressure-controlled mask ventilation versus circle system ventilation resulted in lower (mean ± sd) peak airway pressures (10.6 ± 1.5 cm H2O versus 14.4 ± 2.4 cm H2O; P < 0.001), δ airway pressures (8.5 ± 1.5 cm H2O versus 11.9 ± 2.3 cm H2O; P < 0.001), expiratory tidal volume (650 ± 100 mL versus 680 ± 100 mL; P = 0.001), minute ventilation (10.4 ± 1.8 L/min versus 11.6 ± 1.8 L/min; P < 0.001), and peak inspiratory flow rates (0.81 ± 0.06 L/s versus 1.06 ± 0.26 L/s; P < 0.001) but higher inspiratory time fraction (48% ± 0.8% versus 33% ± 7.7%; P < 0.001) and end-tidal carbon dioxide (34 ± 3 mm Hg versus 33 ± 4 mm Hg; not significant). We conclude that in this model of apneic patients with an unprotected airway, pressure-controlled ventilation resulted in reduced inspiratory peak flow rates and peak airway pressures when compared with circle system ventilation, thus providing an additional patient safety effect during mask ventilation.Keywords
This publication has 15 references indexed in Scilit:
- A Pilot Study to Evaluate the SMART BAG®: A New Pressure-Responsive, Gas-Flow Limiting Bag-Valve-Mask DeviceAnesthesia & Analgesia, 2003
- Effects of decreasing inspiratory flow rate during simulated basic life support ventilation of a cardiac arrest patient on lung and stomach tidal volumesResuscitation, 2002
- Reliability of epigastric auscultation to detect gastric insufflationBritish Journal of Anaesthesia, 2002
- The respiratory system during resuscitation: a review of the history, risk of infection during assisted ventilation, respiratory mechanics, and ventilation strategies for patients with an unprotected airwayResuscitation, 2001
- Influence of tidal volume on the distribution of gas between the lungs and stomach in the nonintubated patient receiving positive-pressure ventilationCritical Care Medicine, 1998
- The current status of ventilation strategies during cardiopul-monary resuscitationCurrent Opinion in Critical Care, 1997
- Mask lung ventilation by ambulance personnel: a performance assessmentCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1994
- The Bicore pulmonary monitorAnaesthesia, 1993
- Introduction to biostatistics: Part 5, statistical inference techniques for hypothesis testing with nonparametric dataAnnals of Emergency Medicine, 1990
- Adverse Respiratory Events in Anesthesia: A Closed Claims AnalysisAnesthesiology, 1990