Sliding mode load frequency control for multi‐area time‐delay power system with wind power integration
Authors:
Open Access
- 25 August 2017
- journal article
- research article
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 11 (18) , 4644-4653
Abstract
The interconnected time‐delay power system has become an important issue for the open communication network. Meanwhile, due to the output power fluctuation of integrated wind energy, load frequency control (LFC) for power system with variable sources and loads has become more complicated. The novel decentralised sliding mode (SM) LFC strategy is proposed for multi‐area time‐delay power system with significant wind power penetration. The appropriate switching surface gain is selected to assure the stability of power system with mismatched uncertainties. The SM controller is constructed to satisfy the hitting condition. At last, the SM controller is proved by using the real‐time digital simulator device under different case of time delay, wind penetration, load disturbance and operating point. The test results show that the proposed SM LFC can reduce frequency deviation and tie‐line power fluctuation effectively.Keywords
This publication has 37 references indexed in Scilit:
- Linear active disturbance rejection-based load frequency control concerning high penetration of wind energyEnergy Conversion and Management, 2015
- Intelligent LFC Concerning High Penetration of Wind Power: Synthesis and Real-Time ApplicationIEEE Transactions on Sustainable Energy, 2013
- Smart grids, renewable energy integration, and climate change mitigation – Future electric energy systemsApplied Energy, 2012
- Frequency Control in Autonomous Power Systems With High Wind Power PenetrationIEEE Transactions on Sustainable Energy, 2012
- Decentralized model predictive based load frequency control in an interconnected power systemEnergy Conversion and Management, 2011
- Impacts of Wind Power Minute-to-Minute Variations on Power System OperationIEEE Transactions on Power Systems, 2008
- Considering Load-Carrying Capability and Wind Speed Correlation of WECS in Generation Adequacy AssessmentIEEE Transactions on Energy Conversion, 2006
- Frequency Deviation of Thermal Power Plants Due to Wind FarmsIEEE Transactions on Energy Conversion, 2006
- Reliability benefit analysis of adding WTG to a distribution systemIEEE Transactions on Energy Conversion, 2001
- Prediction and evaluation of the performance of wind-diesel energy systemsIEEE Transactions on Energy Conversion, 1996