Use of a silver-coated plate to treat a postoperative infection after high tibial osteotomy – a case report
Authors:
Open Access
- 13 March 2024
- journal article
- case report
- Published by Copernicus GmbH in Journal of Bone and Joint Infection
- Vol. 9 (2) , 117-119
Abstract
Unilateral osteoarthritis of the knee can be treated by osteotomy. In case of postoperative infection after high tibial osteotomy, treatment can be challenging and often requires implant removal with the risk of loss of reduction. In the presented case, a 47-year old patient suffered postoperative infection after high tibial osteotomy using an angular stable plate with the need for multiple revision surgeries and anti-infective therapy. Implant exchange to a silver-coated angular plate led to infection control with undisturbed wound healing and further bone consolidation. Full bone consolidation could be achieved radiographically 12 months after the last revision surgery. One-step implant exchange using silver-coated implants could be a promising approach to address postoperative infections after high tibial osteotomy.Keywords
This publication has 13 references indexed in Scilit:
- Incidence and risk factors for surgical site infection after medial opening‐wedge high tibial osteotomy using a locking T‐shape plateInternational Wound Journal, 2023
- Treatment of an infected nonunion with additional fresh fracture of the femur with a silver-coated intramedullary nail: A case reportTrauma & Case Reports, 2022
- Silver-coated megaprosthesis in prevention and treatment of peri-prosthetic infections: a systematic review and meta-analysis about efficacy and toxicity in primary and revision surgeryEuropean Journal of Orthopaedic Surgery & Traumatology, 2020
- Antimicrobial silver-coating for locking plates shows uneventful osteotomy healing and good biocompatibility results of an experimental study in rabbitsInjury, 2020
- Complications Associated With Medial Opening-Wedge High Tibial Osteotomy Using a Locking Plate: A Multicenter StudyThe Journal of Arthroplasty, 2019
- Intramedullary nailing in opening wedge high tibial osteotomy—in vitro test for validation of a method of fixationInternational Orthopaedics, 2018
- Antimicrobial coated implants in trauma and orthopaedics–A clinical review and risk-benefit analysisInjury, 2017
- Preventing Implant-Associated Infections by Silver CoatingAntimicrobial Agents and Chemotherapy, 2016
- Infections after high tibial osteotomyKnee Surgery, Sports Traumatology, Arthroscopy, 2012
- Biofilms: Survival Mechanisms of Clinically Relevant MicroorganismsClinical Microbiology Reviews, 2002