Collinearity and Dimensionality Reduction in Radiomics: Effect of Preprocessing Parameters in Hypertrophic Cardiomyopathy Magnetic Resonance T1 and T2 Mapping
Authors:
- Chiara MarziChiara Marzi
- Daniela MarfisiDMDaniela Marfisi
- Andrea BarucciAndrea Barucci
- Jacopo Del MeglioJMJacopo Del Meglio
- Alessio LilliALAlessio Lilli
- Claudio VignaliCVClaudio Vignali
- Mario MascalchiMMMario Mascalchi
- Giancarlo CasoloGCGiancarlo Casolo
- Stefano DiciottiSDStefano Diciotti
- Antonio Claudio TrainoATAntonio Claudio Traino
- Carlo TessaCTCarlo Tessa
- Marco GiannelliMGMarco Giannelli
Open Access
- 6 January 2023
- journal article
- research article
- Published by MDPI AG in Bioengineering
- Vol. 10 (1) , 80
Abstract
Radiomics and artificial intelligence have the potential to become a valuable tool in clinical applications. Frequently, radiomic analyses through machine learning methods present issues caused by high dimensionality and multicollinearity, and redundant radiomic features are usually removed based on correlation analysis. We assessed the effect of preprocessing—in terms of voxel size resampling, discretization, and filtering—on correlation-based dimensionality reduction in radiomic features from cardiac T1 and T2 maps of patients with hypertrophic cardiomyopathy. For different combinations of preprocessing parameters, we performed a dimensionality reduction of radiomic features based on either Pearson’s or Spearman’s correlation coefficient, followed by the computation of the stability index. With varying resampling voxel size and discretization bin width, for both T1 and T2 maps, Pearson’s and Spearman’s dimensionality reduction produced a slightly different percentage of remaining radiomic features, with a relatively high stability index. For different filters, the remaining features’ stability was instead relatively low. Overall, the percentage of eliminated radiomic features through correlation-based dimensionality reduction was more dependent on resampling voxel size and discretization bin width for textural features than for shape or first-order features. Notably, correlation-based dimensionality reduction was less sensitive to preprocessing when considering radiomic features from T2 compared with T1 maps.Keywords
This publication has 73 references indexed in Scilit:
- The effect of SUV discretization in quantitative FDG-PET Radiomics: the need for standardized methodology in tumor texture analysisScientific Reports, 2015
- Abnormal T2-STIR Magnetic Resonance in Hypertrophic Cardiomyopathy: A Marker of Advanced Disease and Electrical Myocardial InstabilityPLOS ONE, 2014
- A survey on unsupervised outlier detection in high‐dimensional numerical dataStatistical Analysis and Data Mining: An ASA Data Science Journal, 2012
- Intratumor Heterogeneity Characterized by Textural Features on Baseline 18F-FDG PET Images Predicts Response to Concomitant Radiochemotherapy in Esophageal CancerJournal of Nuclear Medicine, 2011
- T2 quantification for improved detection of myocardial edemaJournal of Cardiovascular Magnetic Resonance, 2009
- The effects of breath-holding on pulmonary regurgitation measured by cardiovascular magnetic resonance velocity mappingJournal of Cardiovascular Magnetic Resonance, 2009
- Stability of feature selection algorithms: a study on high-dimensional spacesKnowledge and Information Systems, 2006
- Human Myocardium: Single-Breath-hold MR T1 Mapping with High Spatial Resolution—Reproducibility StudyRadiology, 2006
- The Proof and Measurement of Association Between Two Things.1961
- OCCAM'S RAZORMind, 1915