Comparison of Ice Lined Refrigerators of the different types used in Western part of India under the Universal Immunization Program
Open Access
- 31 August 2025
- journal article
- Published by Indian Association of Preventive and Social Medicine in Indian Journal of Community Health
- Vol. 37 (4) , 584-590
Abstract
Background & Objective: The effectiveness of Ice-Lined Refrigerators (ILRs) is crucial in maintaining the cold chain for vaccines, particularly in India's Universal Immunization Program (UIP). This cross-sectional study aimed to compare the performance of top-and front-opening ILRs in Gujarat, focusing on temperature stability, holdover time, and functionality. Methods: A total of 123 ILRs from various manufacturers were assessed across urban and rural health facilities. Key parameters such as ambient temperature, breakdown frequency, ease of use, and temperature fluctuations during door openings were recorded. Mann-whitney U test/ t-test and Binary logistic regression model were used as statistical methods. Results: Analysis indicated that top-opening ILRs, which made up 72.4% of the sample, performed significantly better in maintaining temperature stability and had a longer holdover time (mean: 5.4hours) compared to front-opening ILRs (mean: 4.3hours). Temperature breaches were more frequent in top-opening models (34.8%) compared to front-opening ones (5.9%), but the front-opening ILRs exhibited a greater temperature rise during door openings. Logistic regression analysis revealed a strong association between longer holdover time and top-opening ILRs. The study also found infrastructure and training gaps at some facilities, with only 57.7% of ILRs equipped with functional temperature monitoring systems, and many health workers lacking updated training. The findings suggest that top-opening ILRs are more reliable for cold chain management, though further investigation into front-opening models is warranted. Conclusion: For future cold chain management, prioritize top-opening ILRs for their reliability, increase AMC coverage for consistent maintenance, and enhance training for personnel on ILR handling, especially with newer models. Additionally, invest in backup-power and temperature monitoring equipment to prevent temperature breaches, particularly in remote areas.Keywords
This publication has 7 references indexed in Scilit:
- Using new cold chain technologies to extend the vaccine cold chain in India: Equipment performance, acceptability, systems fit, and costsVaccine: X, 2023
- A cross sectional study to assess the functioning of cold chain in a tribal district of central IndiaInternational Journal Of Community Medicine And Public Health, 2018
- Evaluation of cold chain and logistics management practice in Durg district of Chhattisgarh: pointer from Central IndiaInternational Journal Of Community Medicine And Public Health, 2017
- Factors associated with the exposure of vaccines to adverse temperature conditions: the case of North West region, CameroonBMC Research Notes, 2015
- Status of vaccine cold chain maintenance in Delhi, IndiaIndian Journal of Medical Microbiology, 2010
- Immunization in practice, a practical guide for health staffArchives of Disease in Childhood, 2005
- Evaluation, Awareness, Practice and Management of Cold Chain at the Primary Health Care Centers in Coastal South IndiaJournal of Nepal Paediatric Society, 1970