Parallel Headspace Extraction onto Etched Sorbent Sheets Prior to Ambient-Ionization Mass Spectrometry for Automated, Trace-Level Volatile Analyses
Authors:
- 26 October 2018
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 90 (22) , 13806-13813
Abstract
Headspace (HS) extraction and preconcentration of volatiles by solid-phase microextraction (SPME) can improve the sensi-tivity and selectivity of ambient ionization-mass spectrometry approaches like Direct Analysis in Real Time (DART), but previous approaches to HS-SPME-DART-MS have been challenging to automate. This report describes the production of inexpensive, reusable solid-phase mesh enhanced sorption from headspace (SPMESH) sheets by laser-etching mesh patterns into polydimethylsiloxane (PDMS) sheets. Parallel headspace extraction of volatiles from multiple samples can be achieved by positioning the SPMESH sheets over multiwell plates and then attaching to a positioning stage for automated DART-MS quantitation. Using three representative odorants (3-isobutyl-2-methoxypyrazine, linalool, and methyl anthranilate), we achieved µg/L – ng/L detection limits with SPMESH-DART-MS, with the DART-MS step requiring only 17 min for 24 sam-ples. Acceptable repeatability (24% or less day-to-day variation) and excellent recovery from a grape matrix (99-106%) could be achieved. Through use of a Teflon gasket and stainless steel spacers, cross-contamination between the headspaces of adjacent wells could be limited to roughly 1%. Optimum SPMESH extraction and desorption parameters were determined by response surface methodology. In summary, sheet-based SPMESH provides a sensitive, readily automated approach for coupling with DART-MS and achieving high-throughput trace-level volatile analysesKeywords
Funding Information
- National Institute of Food and Agriculture (2017-67007-25940)
- E and J Gallo Winery
- New York Wine and Grape Foundation (I-34)
This publication has 32 references indexed in Scilit:
- Review of geometries and coating materials in solid phase microextraction: Opportunities, limitations, and future perspectivesAnalytica Chimica Acta, 2017
- Open Port Probe Sampling Interface for the Direct Coupling of Biocompatible Solid-Phase Microextraction to Atmospheric Pressure Ionization Mass SpectrometryAnalytical Chemistry, 2017
- Solid Phase Mesh Enhanced Sorption from Headspace (SPMESH) Coupled to DART-MS for Rapid Quantification of Trace-Level VolatilesAnalytical Chemistry, 2016
- Direct Coupling of Solid-Phase Microextraction with Mass Spectrometry: Sub-pg/g Sensitivity Achieved Using a Dielectric Barrier Discharge Ionization SourceAnalytical Chemistry, 2016
- A critical review of the state of the art of solid-phase microextraction of complex matrices II. Food analysisTrAC Trends in Analytical Chemistry, 2015
- Nature’s Chemical Signatures in Human Olfaction: A Foodborne Perspective for Future BiotechnologyAngewandte Chemie International Edition, 2014
- Evaluating a direct swabbing method for screening pesticides on fruit and vegetable surfaces using direct analysis in real time (DART) coupled to an Exactive benchtop orbitrap mass spectrometerAnalytical and Bioanalytical Chemistry, 2012
- Challenging applications offered by direct analysis in real time (DART) in food-quality and safety analysisTrAC Trends in Analytical Chemistry, 2011
- Ambient mass spectrometry employing a DART ion source for metabolomic fingerprinting/profiling: a powerful tool for beer origin recognitionMetabolomics, 2010
- The influence of material and mesh characteristics on transmission mode desorption electrospray ionizationJournal of the American Society for Mass Spectrometry, 2008