Simulated Bioprosthetic Heart Valve Deformation under Quasi-Static Loading
- 14 July 2005
- journal article
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 127 (6) , 905-914
Abstract
For more than 40years, the replacement of diseased natural heart valves with prosthetic devices has dramatically extended the quality and length of the lives of millions of patients worldwide. However, bioprosthetic heart valves (BHV) continue to fail due to structural failure resulting from poor tissue durability and faulty design. Clearly, an in-depth understanding of the biomechanical behavior of BHV at both the tissue and functional prosthesis levels is essential to improving BHV design and to reduce rates of failure. In this study, we simulated quasi-static BHV leaflet deformation under 40, 80, and 120mmHg quasi-static transvalvular pressures. A Fung-elastic material model was used that incorporated material parameters and axes derived from actual leaflet biaxial tests and measured leaflet collagen fiber structure. Rigorous experimental validation of predicted leaflet strain field was used to validate the model results. An overall maximum discrepancy of 2.36% strain between the finite element (FE) results and experiment measurements was obtained, indicating good agreement between computed and measured major principal strains. Parametric studies utilizing the material parameter set from one leaflet for all three leaflets resulted in substantial variations in leaflet stress and strain distributions. This result suggests that utilization of actual leaflet material properties is essential for accurate BHV FE simulations. The present study also underscores the need for rigorous experimentation and accurate constitutive models in simulating BHV function and design.Keywords
This publication has 40 references indexed in Scilit:
- Calcification of Tissue Heart Valve Substitutes: Progress Toward Understanding and PreventionThe Annals of Thoracic Surgery, 2005
- The effects of collagen fiber orientation on the flexural properties of pericardial heterograft biomaterialsBiomaterials, 2005
- Triglycidylamine Crosslinking of Porcine Aortic Valve Cusps or Bovine Pericardium Results in Improved Biocompatibility, Biomechanics, and Calcification ResistanceThe American Journal of Pathology, 2005
- A nonlinear anisotropic model for porcine aortic heart valvesJournal of Biomechanics, 2001
- Nonaldehyde Sterilization of Biologic Tissue for Use in Implantable Medical DevicesASAIO Journal, 1997
- In vitro endothelialization of photooxidatively stabilized xenogeneic pericardiumThe Annals of Thoracic Surgery, 1995
- Stabilization of pericardial tissue by dye‐mediated photooxidationJournal of Biomedical Materials Research, 1994
- Pathology of Substitute Heart Valves: New Concepts and DevelopmentsJournal of Cardiac Surgery, 1994
- Numerical simulation of leaflet flexure in bioprosthetic valves mounted on rigid and expansile stentsJournal of Biomechanics, 1993
- A mechanical analysis of the closed Hancock heart valve prosthesisJournal of Biomechanics, 1988