Closed loop full process management and application of body fluid specimens in hospitalised patients
Open Access
- 8 May 2026
- journal article
- Published by BMJ in BMJ Open Quality
- Vol. 15 (2) , e003740
Abstract
Objective: To develop and implement a closed-loop full-process management system for body fluid specimens in hospitalised patients, with the aim of improving submission timeliness and specimen quality. Methods: A multidisciplinary inpatient specimen management team was established to analyse the causes of inefficiencies in the collection-to-submission process of body fluid specimens. Based on these findings, targeted interventions were formulated and implemented in February 2025. The preanalytical turnaround times and unqualified specimen rate before and after implementation were compared. Results: After implementing the closed-loop management system, the delayed submission rate of body fluid specimens decreased from 15.62% to 5.8% and the unqualified specimen rate decreased from 0.70% to 0.39%. The improvement in submission timeliness and specimen quality was statistically significant (p<0.05). All indicators showed significant differences at 3 and 6 months after intervention compared with before intervention (p<0.05). Conclusion: The implementation of a closed-loop full-process management system for body fluid specimens effectively improved the timeliness of specimen submission, reduced delays and decreased the occurrence of unqualified specimens, thereby enhancing patient safety.Keywords
This publication has 13 references indexed in Scilit:
- Application Effectiveness of a Pre-Analytical Quality Management Pathway Based on the Structure–Process–Outcome ModelJournal of Multidisciplinary Healthcare, 2025
- Implementation and performance evaluation of an integrated specimen referral system in Burkina Faso using the national courier services (2020–2022)Frontiers in Public Health, 2024
- Preanalytical Errors in Clinical Biochemistry Laboratory and Relationship With Hospital Departments and Staff: A Record-Based StudyJournal of Patient Safety, 2023
- The impact of environmental factors on external and internal specimen transportClinical Biochemistry, 2022
- Reducing Errors in Radiology Specimen Labeling Through Use of a Two-person CheckCurrent Problems in Diagnostic Radiology, 2020
- Preservation of Neisseria gonorrhoeae: should swabs be refrigerated or not? Neisseria gonorrhoeae preservationJournal of Microbiological Methods, 2018
- Effectiveness of Preanalytic Practices on Contamination and Diagnostic Accuracy of Urine Cultures: a Laboratory Medicine Best Practices Systematic Review and Meta-analysisClinical Microbiology Reviews, 2016
- Specimen rejection in laboratory medicine: Necessary for patient safety?Biochemia Medica, 2015
- Clinical Consequences of Specimen Rejection: A College of American Pathologists Q-Probes Analysis of 78 Clinical LaboratoriesArchives of Pathology & Laboratory Medicine, 2014
- Quality Improvements in the Preanalytical Phase: Focus on Urine Specimen WorkflowClinics In Laboratory Medicine, 2008