Optimizing laparoscopic task efficiency: the role of camera and monitor positions
- 12 April 2007
- journal article
- Published by Springer Nature in Surgical Endoscopy
- Vol. 21 (6) , 980-984
Abstract
Alterations of video monitor and laparoscopic camera position may create perceptual distortion of the operative field, possibly leading to decreased laparoscopic efficiency. We aimed to determine the influence of monitor/camera position on the laparoscopic performance of surgeons of varying skill levels. Twelve experienced and 12 novice participants performed a one-handed task with their dominant hand in a modified laparoscopic trainer. Initially, the camera was fixed directly in front of the participant (0°) and the monitor location was varied between three positions, to the left of midline (120°), directly across from the participant (180°), and to the right of the midline (240°). In the second experiment monitor position was constant straight across from the participant (180°) while the camera position was adjusted between the center position (0°), to the left of midline (60°), and to the right of midline (300°). Participants completed five trials in each monitor/camera setting. The significance of the effects of skill level and combinations of camera and monitor angle were evaluated by analysis of variance (ANOVA) for repeated measures using restricted maximum likelihood estimation. Experienced surgeons completed the task significantly faster at all monitor/camera positions. The best performance in both groups was observed when the monitor and camera were located at 180° and 0°, respectively. Monitor positioning to the right of midline (240°) resulted in significantly worse performance compared to 180° for both experienced and novice surgeons. Compared to 0° (center), camera position to the left or the right resulted in significantly prolonged task times for both groups. Novice subjects also demonstrated a significantly lower ability to adjust to suboptimal camera/monitor positions. Experienced subjects demonstrated superior performance under all study conditions. Optimally, the camera should be directly in front and the monitor should be directly across from a surgeon. Alternatively, the monitor/camera could be placed opposite to the surgeon’s non-dominant hand. The suboptimal camera/monitor conditions are especially difficult to overcome for inexperienced subjects. Monitor and camera positioning must be emphasized to ensure optimal laparoscopic performance.Keywords
This publication has 16 references indexed in Scilit:
- The role of mental rotation and memory scanning on the performance of laparoscopic skillsSurgical Endoscopy, 2006
- Screen height as an ergonomic factor in laparoscopic surgerySurgical Endoscopy, 2005
- Monitor position in laparoscopic surgerySurgical Endoscopy, 2005
- Monitor height affects surgeons' stress level and performance on minimally invasive surgery tasks.2005
- Video-assisted surgery represents more than a loss of three-dimensional visionThe American Journal of Surgery, 2005
- Comparison of orthodox versus off-optical axis endoscopic manipulationsSurgical Endoscopy, 2001
- Ergonomic principles of task alignment, visual display, and direction of execution of laparoscopic bowel suturingSurgical Endoscopy, 2001
- Experienced Laparoscopic Surgeons are Automated to the “Fulcrum Effect”: An Ergonomic DemonstrationEndoscopy, 1999
- Perceptual-motor coordination in an endoscopic surgery simulation.Surgical Endoscopy, 1999
- Image Rotation and Reversal - Major Obstacles In Learning Intracorporeal Suturing and Knot-Tying1999